XBL series0 pages
Features:
•t Directly Connected, Discrete Protection Elements
Between All Possible Modes
•tUL 1449 Third Edition Listed (Sept 2009)
•t600 & 900kA per phase ratings
•tType 1 SPD –
–– All UL required OCP & Safety Coordination included inside
–– Can be installed line-side or load-side of main disconnect
•t20kA Inominal (In)
•t200kA SCCRs (most models)
•tUL 96A Lightning Protection Master Label compliant
•tRotary Disconnect Switch included as Standard Equipment
•tDual Redundant Replaceable Module Construction
•tAll MOV suppression elements monitored
Performance Specifications
•tDirectly Connected, Discrete Protection Elements
Between All Possible Modes with True 10-Mode
Protection
•t Surge Capacitiest L-Nt
L-Gt
L-Lt
N-G
600kA/phaset 200kAt200kAt200kAt200kA
900kA/phaset 300kAt300kAt300kAt300kA
•t UL 1449 Third Edition Listed, UL 1283 and cUL
•t UL 1449-3 Type 1 SPD
•t UL 1449-3 tested Inominal (In): 20kA
•t UL 1449-3 tested SCCR: 200kA & 100kA
•t UL 1449-3 Voltage Protection Ratings (VPRs):
–– 208Y/120V: as low as 700V
–– 480Y/277V: as low as 1200V
•t Less than 1 nanosecond response time
•t Repetitive Impulse: 5,000 hits
•tAC Sinewave True Tracking Filter with EMI/RFI
•tFiltering up to -50dB from 10kHz to 100MHz
Diagnostic Monitoring
•t 100% monitoring – Every MOV is monitored, incl. N-G
•t Green LED Status indicator per phase
•t Red LED service indicator
•t Audible Alarm with Silence Switch
•t Test Function: toggles red service LED, audible alarm &
dry contact (if equipped)
•t N-G overvoltage detection
•t Phase Loss monitoring
•t Electrically isolated diagnostic circuitry
•t Form C Dry Contacts, 240V, 5A (two sets)
•t Optional Surge Counter, six-digit LCD, with test function,
reset & no-maintenance Eprom memory
Design Features
•t Designed, Manufactured & Tested consistent with:
–– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
–– NEMA LS-1
–– NEC Article 285
–– IEC 61643, CE
•t High Energy Parallel Design for Category C3 & C-High applications
•t For External Mounting next to Switchgear, Motor Controls Centers
or Panelboards
•t Individually Fused & Thermally Protected MOVs
•t Large-Block, 34mm square, 50kA MOVs
•t Dual Redundant Replaceable Module Construction
•t Solid State Bidirectional Operation
Physical Specifications
•t Relative Humidity Range: 0 -95% non-condensing
•t Operating Frequency: 47-63Hz
•t Operating Temperature: -25°C (-15°F) to +60°C (140°F)
•t Weight: 52 lbs (23.6 kg)
•t Standard NEMA 1/12/3R/4 enclosure
•t Standard size: 20” x 20” x 7 (50.8cm x 50.8cm x 19cm)
.5”
•t Lug size: #6 - #1/0 AWG
•t Typical connection: #6 AWG and 60A breaker
Quality, Standards & Validation
•t UL 1449 Third Edition, cUL, UL 1283
•t UL file: VZCA.E321351 at www.UL.com
•t RoHS-compliant
•t IEC 61643, CE
•t 10 year warranty (longer optional)
•t Burn-In tested Prior to Shipment
•t ISO 9001:2008 Quality Management System
•t ISO 17025:2005 Laboratory Qualification
•t Made in USA
Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com