Features:
•tUL 1449 Third Edition Listed (Sept 2009)
•t400kA – 1,000kA per phase ratings
•tType 1 SPD –
–– All UL required OCP & Safety Coordination included inside
–– Can be installed line-side or load-side of main disconnect
•t20kA Inominal (In)
•t200kA SCCRs (most models)
•tUL 96A Lightning Protection Master Label compliant
•tRotary Disconnect Switch included as Standard Equipment
•tDual Redundant Replaceable Modules
•tVoltage Specific Design – Highly configurable
•tAll MOV suppression elements monitored
Performance Specifications
•t Surge Capacitiest L-Nt
L-Gt
N-G
400kA/phaset 200kAt200kAt200kA
600kA/phaset 300kAt300kAt300kA
800kA/phaset 400kAt400kAt400kA
1000kA/phaset 500kAt500kAt500kA
•t UL 1449 Third Edition Listed, UL 1283 and cUL
•t UL 1449-3 Type 1 SPD
•t UL 1449-3 tested Inominal (In): 20kA
•t UL 1449-3 tested SCCR: 200kA & 100kA
•t UL 1449-3 Voltage Protection Ratings (VPRs):
–– 208Y/120V: as low as 700V
–– 480Y/277V: as low as 1200V
•t Less than 1 nanosecond response time
•t Repetitive Impulse: 5,000 hits
•t AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz
Diagnostic Monitoring
•t 100% monitoring – Every MOV is monitored, incl. N-G
•t Green LED Status indicator per phase
•t Red LED service indicator
•t Audible Alarm with Silence Switch
•t Test Function: toggles red service LED, audible alarm &
dry contact (if equipped)
•t N-G overvoltage detection
•t Phase Loss monitoring (toggles LED & dry contacts)
•t Electrically isolated circuitry ensures surges do not damage
diagnostics
•t Form C Dry Contacts, 240V, 5A (two sets)
•t Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance Eprom memory
Design Features
•t Designed, Manufactured & Tested consistent with:
–– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
–– NEMA LS-1
–– NEC Article 285
–– IEC 61643, CE
•t High Energy Parallel Design for Category C3 & C-High
applications
•t For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
•t Individually Fused & Thermally Protected MOVs
•t Large-Block, 34mm square, 50kA MOVs
•t Dual Replaceable Module Construction
•t Solid State Bidirectional Operation
Physical Specifications
•t Relative Humidity Range: 0 -95% non-condensing
•t Operating Frequency: 47-63Hz
•t Operating Temperature: -25°C (-15°F) to +60°C (140°F)
•t Weight: 52 lbs (23.6 kg)
•t Standard NEMA 1/12/3R/4 enclosure
•t Standard size: 20” x 20” x 7 (50.8cm x 50.8cm x 19cm)
.5”
•t Lug size: #6 - #1/0 AWG
•t Typical connection: #6 AWG and 60A breaker
Quality, Standards & Validation
•t UL 1449 Third Edition, cUL, UL 1283
•t UL file: VZCA.E321351 at www.UL.com
•t RoHS-compliant
•t IEC 61643, CE
•t 10 year warranty (longer optional)
•t Burn-In tested Prior to Shipment
•t ISO 9001:2008 Quality Management System
•t ISO 17025:2005 Laboratory Qualification
•t Made in USA