XAL series0 pages
Features:
•t Directly Connected, Discrete Protection Elements t
Between All Possible Modes
•tUL 1449 Third Edition Listed (Sept 2009)
•t150kA – 450kA per phase ratings
•tType 1 SPD –
–– All UL required OCP & Safety Coordination included inside
–– Can be installed line-side or load-side of main disconnect
•t20kA Inominal (In)
•t200kA SCCRs (most models)
•tUL 96A Lightning Protection Master Label compliant (@20kA In)
•tAll MOV suppression elements monitored
Performance Specifications
•tDirectly Connected, Discrete Protection Elements
Between All Possible Modes with True 10-Mode Protection
•t Surge Capacitiest L-Nt
L-Gt
L-Lt
N-G
150kA/phaset 50kAt50kAt50kAt50kA
300kA/phaset 100kAt100kAt100kAt100kA
450kA/phaset 150kAt150kAt150kAt150kA
•t UL 1449 Third Edition Listed, cUL, UL 1283 R/C
•t UL 1449-3 Type 1 SPD (cUL Type 2 optional)
•t UL 1449-3 tested Inominal (In): 20kA
•t UL 1449-3 tested SCCR: 200kA & 100kA
•t UL 1449-3 Voltage Protection Ratings (VPRs):
–– 208Y/120V: as low as 600V
–– 480Y/277V: as low as 1000V
•t Less than 1 nanosecond response time
•t Repetitive Impulse: 5,000 hits
•tAC Sinewave True Tracking Filter with EMI/RFI Filtering
up to -50dB from 10kHz to 100MHz
Diagnostic Monitoring
•t 100% monitoring – Every MOV is monitored, incl. N-G
•t Green LED Status indicator per phase
•t Red LED service indicator
•t Audible Alarm with Silence Switch
•t Test Function: toggles red service LED, audible alarm &
dry contact (if equipped)
•t N-G overvoltage detection
•t Phase Loss monitoring
•t Electrically isolated diagnostic circuitry
•t Form C Dry Contacts, 240V, 5A (two sets)
•t Optional Surge Counter, six-digit LCD, with test function,
reset & no-maintenance Eprom memory
Design Features
•t Designed, Manufactured & Tested consistent with:
–– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
–– NEMA LS-1
–– NEC Article 285
–– IEC 61643, CE
•t High Energy Parallel Design for Category C3 & C-High
applications
•t For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
•t Individually Fused & Thermally Protected MOVs
•t Large-Block, 34mm square, 50kA MOVs
•t Replaceable Module Construction
•t Solid State Bidirectional Operation
Physical Specifications
•t Relative Humidity Range: 0 -95% non-condensing
•t Operating Frequency: 47-63Hz
•t Operating Temperature: -25°C (-15°F) to +60°C (140°F)
•t Weight: 24 lbs (11 kg)
•t Standard NEMA 1/12/3R/4 enclosure
•t Standard size: 12” x 12” x 6.5” (30.5cm x 30.5cm x 16.5cm)
•t Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
•t Typical connection: #6 AWG and 60A breaker
Quality, Standards & Validation
•t UL 1449 Third Edition, cUL, UL 1283
•t UL file: VZCA.E321351 at www.UL.com
•t RoHS-compliant
•t IEC 61643, CE
•t 10 year warranty (longer optional)
•t Burn-In tested Prior to Shipment
•t ISO 9001:2008 Quality Management System
•t ISO 17025:2005 Laboratory Qualification
•t Made in USA
Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com