DLX9.4KK.10 pages
DLX9.4KK.1
High Energy-optimized Compressor
R600a
220-240V 50Hz
General
Code number
102H4159
Approvals
EN 60335-2-34 with Annex AA
Compressors on pallet
100
Application
Application
LBP
Frequency
Hz
50
60
Evaporating temperature
°C
-35 to -10
–
V
198 - 254
–
Voltage range
Max. condensing temperature continuous (short)
°C
60 (70)
–
Max. winding temperature continuous (short)
°C
105 (115)
–
Hz
50
60
Cooling requirements
Frequency
Application
LBP MBP HBP LBP MBP HBP
32°C
S
–
–
–
–
–
38°C
S
–
–
–
–
–
43°C
S
–
–
–
–
–
Remarks on application:
St =tStatic cooling normally sufficient
Ot =tOil cooling
F1t =tFan cooling 1.5 m/s
tt (compressor compartment temperature
tt equal to ambient temperature)
F2t =tFan cooling 3.0 m/s necessary
SGt = Suction gas cooling normally sufficent
–t = not applicable in this area
Motor
Motor type
RSCR
LRA (rated after 4 sec. UL984), HST | LST
A
–
Cut in Current, HST | LST
A
–
3.1
6.1
Resistance, main | start winding (25°C)
Ω
20.2
22.8
Design
Displacement
cm3
9.38
Oil quantity (type)
cm3
155 (mineral)
Maximum refrigerant charge
g
Free gas volume in compressor
cm
Weight without electrical equipment
150
1400
3
kg
9.4
Dimensions
Height
mm A
175
B
169
B1
–
B2
Suction connector
location/I.D. mm | angle C
material | comment
Process connector
–
6.2 | 18°
Cu-plated steel | Rubber plug
4.5 | 60°
material | comment
Discharge connector
location/I.D. mm | angle D
Copper | Rubber plug
5.0 | 25°
material | comment
Oil cooler connector
location/I.D. mm | angle E
Copper | Rubber plug
location/I.D. mm | angle F
–
material | comment
Connector tolerance
I.D. mm
–
±0.09, on 5.0 +0.12/+0.22
on 4.5 +0.10/-0.20
Remarks:
April 2012
DES.D.500.N2.02
1/2
"