18000 pages
1800 Oxygen Analyser
nnnnThe Servomex 1800 analyser is a
nnnnstable, accurate and highly specific
nnnnoxygen analyser for safe areas.
nnnn• Designed for safe area oxygen
nnnnanalysis
nnnn• Low maintenance and
nnnnre-calibration requirements
nnnn• Range of alarm outputs to aid
nnnnintegration with other systems
nnnn• Easy to set up and operate
nnnn• Special versions for solvent
nnnnbearing samples
nnnn• Special high flow rate cell
nnnnoption
nnnnSpecification | |
Gases Measured: | o2 |
PERFORMANCE Technology: Range: Intrinsic Error (accuracy): Linearity: Repeatability: Response time (T9Q) Zero drift/ week: Span drift/ week: SIGNAL OUTPUTS Analogue: Alarms: Concentration Sample flow fail PHYSICAL Dimensions:(W x D x H) Weight: Hazardous area Classification: Ingress Protection: Mounting: | Paramagnetic transducer 0-100% 02 <0.2% of reading or 0.05% 02 1 <0.05% 02 2 <0.1% of reading or 0.05% 02 1 4 to 8 seconds 3 <0.05% 02 <1 % of reading or 0.05% 02 1 One 4-20 rrA, isolated & one 0-1V dc, non-isolated. Ranges selectable from 0 - 2.5, 5, 10, 25 and 100% 02 Two volt free changeover relays rated 250Vac/3A or 28Vdc (non inductive) maximum and 5V/10mA ac/dc minimum One volt free changeover relay rated 250Vac/3A or 28Vdc (non inductive) maximum and 5V/10mA ac/dc minimum 448mm x 229mm x 235 mm / 17.6" x 9" x 9.25" 26 kg / 57 lbs Non-Hazardous Areas only IP 66 / NEMA 4X Wall or Panel |
whichever is the greater
nnnnnherently linear, value dependant on calibration gases
nnnndependant on configuration
nnnnSERVOMEX ^
"