Digital temperature data logger K J E T thermocouple recorder Tecpel DTM-319A0 pages
The 4 - Input Digital Thermometer
nnnnDTM-319A
nnnn4-Input
nnnnK J E T Temperature Data Logger
nnnn-200 ~ 1370°C (-328 ~ 2501°F)
nnnn-150 ~ 1000°C (-238 ~ 1832°F)
nnnn-150 ~ 750°C (-238 ~ 1382°F)
nnnn-180 ~ 400°C (-292 ~ 752°F)
nnnnSummary:
nnnnThe 4 - Input Digital Thermometer
nnnnDTM-319A is a battery-powered
nnnnK, J, E, T Type temperature data
nnnnlogger with sensor already built
nnnninside the device. For sure, the
nnnnproduct is a compact, which is
nnnneasy for users to carry it
nnnneverywhere.
nnnnFurthermore, it is a practical
nnnndevice without difficult
nnnnmanipulation skills needed;
nnnncustomers can use this data logger in an efficient way. Last
nnnnbut not least, the item can measure temperature from
nnnn-200°C ~ 1,372°C, which is ideal for all applications,
nnnnespecially in some circumstances requiring precise
nnnnoperation and measurement.
nnnnFeatures:
nnnn)> 4-channel thermocouples can be used.
nnnn» Resolution 0.1°C or 0.1°F< 1000 ° (>1000 °,1°C)
nnnn)> Temperature scale: °C or °F user-selectable.
nnnn)> Sensor K, J, E, T type Thermocouple probe.
nnnn)> Sampling rate 1 seconds per testing circle.
nnnn)> llsolated input protection up to 250Vac between any
nnnntwo inputs .
nnnn» Back light button .
nnnn)> 4 Digit LCD display for every tested point.
nnnn)> Auto Power off.
nnnn)> Automatic low battery indication.
nnnn)> USB Computer interface.
nnnn)> Standard Tripod mount connector.
nnnntnS. MIN MAX AVG
nnnn® T1QQQD'F
nnnnQ OQO.Dc
nnnnK T2
nnnnJ -
nnnnE
nnnnT T3
nnnnT1-T2
nnnnT4
nnnnREC -
nnnnFULL
nnnn888.8
nnnn888.8-c
nnnn8 88.8'
nnnn8 8:8.8°c
nnnnSpecifications:
nnnnMeasurement Channel : 2 Channel | |
Measurement range = K: -200 ~1372°C (- 328 ~ 2501 °F) J: -150°C~1000°C (- 238 ~ 1832°F) E: -150°C~750°C (- 238 ~ 1382°F) T: -180°C~400°C (- 292 ~ 752°F) | |
Resolution = 0.1 °C/°F < 1000°, 1°C/°F ^1000° | |
Accuracy : ±(0.1% of reading+0.7°C) ±(0.1% of reading+1.4°F) Below-100°C (-148°F) ±(0.4% of reading +0.7°C) ±(0.4% of reading +1.4°F) | |
Temperature coefficient : 0.01% of reading + 0.05°C per°C (<18°C or>28°C) | |
Sample rate | 1 time per second |
Logging Capacity | 16,000X4 Ch. |
Recording | 1 Seconds ~ 60 Minutes |
Battery type | 9V Battery |
Battery lifetime | Approx. 30 hours (alkaline battery) |
AC adapter | 9 VDC (8-10VDC Max) |
Operation temperature | -10 to 50°C (14 to 122°F) |
Operation humidity | 10 to 90%RH (no condensing) |
Storage temperature | -40 to 60°C(-40 to140°F) |
Storage humidity | 10 to 75% RH |
Dimensions/ Weight | 197 x 65 x 36mm / Approx. 31 Og |
Standard Accessories | Instruction manual, 9V Battery, windows software, carrying case, USB cable, K Type Bead Probe x 2 PCS. |
Optional Accessories : AC/DC adapter |
Accuracy is specified for ambient temperatures between 18°C (64°F) and 28°C
nnnn(82°F). The above specifications do not include thermocouple sensor error.
nnnnTECPEL Co., Ltd.
nnnnTEL: 886-2-27375866 FAX : 886-2-27373343
nnnnWWW.TECPEL.COM WWW.OKA.COM.TW
"