TRPGR30ENATGB 32-mm LF Glass-Encapsulated Transponder, Read Only, EN 148030 pages
TRPGR30ENATGB
www.ti.com
SCBS899 – OCTOBER 2013
32-mm Low-Frequency Glass-Encapsulated Transponder, Read Only,
EN 14803 Numbering
Check for Samples: TRPGR30ENATGB
FEATURES
DESCRIPTION
•
Texas Instruments 32-mm low-frequency (LF) glass
transponders provide superior performance and
operate at a resonance frequency of 134.2 kHz. The
products are compliant to ISO 11784 and ISO 11785
global open standards. Texas Instruments LF glass
transponders are manufactured with TI's patented
tuning process to provide consistent read
performance. Prior to delivery, the transponders
undergo complete functional and parametric testing to
provide the high quality customers have come to
expect from TI.
1
•
•
•
•
Best-in-Class Performance Through HalfDuplex (HDX) Technology
Patented Transponder Tuning Provides Stable
and High Read Performance
80-Bit Read-Only Type
EN 14803 Numbering
Insensitive to Almost All Nonmetallic Materials
APPLICATIONS
•
Waste Container Management
Absolute Maximum Ratings (1)
over operating free-air temperature range (unless otherwise noted)
TRPGR30ENATGB
TA
Operating temperature
–25°C to 70°C
TSTG
Storage temperature
–40°C to 85°C
(1)
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Specifications is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Specifications
PARAMETER
TRPGR30ENATGB
Functionality
Read only
Memory (bits)
80 (64-bit unique ID + 16-bit BCC)
Memory (pages)
1
Resonance frequency
134.6 kHz
Modulation
FSK (frequency shift keying) 134.2 kHz and 124.2 kHz
Transmission principle
HDX (half duplex)
Power source
Powered from the reader signal (battery-less)
Typical reading range
≤110 cm (1)
Typical reading time
70 ms
Case material
Glass
Protection glass
Hermetically sealed
EMC
Programmed code is not affected by natural electromagnetic interference or x-rays
Signal penetration
Transponder can be read through almost all nonmetallic material
Mechanical shock
IEC 60068-2-32 free-fall drop test, 20 times from 1.5-m height
Dimensions
Ø 3.85 ± 0.05 mm x 31.2 ± 0.6 mm
Weight
0.8 g
(1)
Depends on RF regulation in country of use, the reader antenna configuration, and the environmental conditions.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2013, Texas Instruments Incorporated
"