Socan - Split Core Current Sensors SCY6 50A..500A0 pages
Socan SCY6 technical parameters
Open Loop Current Sensor
SCY6-
Model
Parameters(25°C)
100A
200A
300A
500A
Nominal Rms Current (Ipn)
±100AT
±200AT
±300AT
±500AT
Measuring Range (Ip)
300AT
600AT
750AT
1000AT
10kΩ
Load resistance Rmax
≥
Supply Voltage
±4V or ±5V
Working voltage
DC ±12V~±15V(±5%)
Accuracy @ Ta=25°C
±1% FS
Linearity @ Ta=25°C
±1% FS
2.5kVrms/50Hz/min
Withstand voltage
Offset Voltage
Offset temperature
characteristics
Themal drift of Vo
Hysteresis offset
< ±30mV
<±15mV
< ±0.1%/°C
<±0.05%
< ±2mV/°C
< ±1mV/°C
<30mV
< 20mV (if=F.S. 0<--- --->Norminal RMS Current)
Reponse time
Current consumption
< 5uS
<±15mA
Operating temperature
-20~+80 °C
Storage temperature
-40~+85 °C
Dimension
Instructions
1. SCY6 Series 's up and down can open and close without removing the busbar line, easy to install.
2. Based on open-loop principle,it can measure DC, AC and Pulse current.
3. Square perforation, mainly measure wire conductor current.
4. Features: High accuracy, low power consumption, high libablity and stronge overload capacity.
Caution: Incorrect wiring may damage the sensor