Socan Close loop current sensor SCB6 Series0 pages
Shenzhen Socan Technologies Co.,ltd T:86‐755‐86242301 F:86‐755‐86242301 W:WWW.SZSOCAN.COM @:SALES@SZSOCAN.COM
SCB6-50A/100A Close Loop Hall Effect Current Sensor
Standard model
Window: 15.2*7.2
Socan SCB6 technical parameters
Magnetic Balance Hall Close Loop Current Sensor
SCB6-50A
SCB6-100A
Primary nominal r.m.s.
current(Ipn)
±50AT
±100AT
Measuring Range (Ip)
75AT
150AT
50~100Ω
20~80Ω
Model
Parameters(25°C)
Road Resistance Rmax
±50mA
Output current
Turns Ratio
Measuring Resistance
1:1000
1: 2000
80Ω
120KΩ
DC
Working voltage
±12V or ±15V (±5%)
Accuracy @ Ta=25°C
±0.5% FS
Linearity @ Ta=25°C
±0.1% FS
Offset Voltage
< ±0.2mA
< ±0.1mA
< ±0.2%/°C
Offset temperature
characteristics
Thermal drift of Vo
Typical values ± 0.1mA, maximum ±0.5mA
>100A/us
Di/Dt following accuracy
DC ~100kHz
Bandwidth
< 1uS
Response time
Hysteresis offset
Typical values ± 0.05mA, maximum ±0.25mA
< 0.5mA
(if=F.S.
Withstand voltage
Current consumption
0<--- --->Nominal RMS Current)
3kVrms/50Hz/min
10mA + output current
Operating temperature
-20~+80 °C
Storage temperature
-40~+85 °C
Dimensionin mm. 1mm=0.0394 inch):
"