LLX20 pages
dynaforTM range LLX2
technical
data sheet
ref. :
rev. n° :
date :
page :
Electronic dynamometer
with removable display unit
W.L.L. : 0.5 to 10 t
Description
Range of precision electronic dynamometers
appliances with removable display unit. The radio
connection (2.4 G.Hertz) with 80 m in open field, working range is permanent between the unit and removable display unit.
The specific, patented shape of the attaching head
enables either standard shackles or standardised
accessories for chains.
The dynamometers of this range function in all positions for the measurement of force and suspended for
weighing purposes.
The LLX 2 is available in two versions: Standard version with interlinking anchoring rings in the perpendicular surfaces, or an optional version with the anchoring
rings both on the same side.
The standard version enables articulation of lifting
accessories on both sides, thus avoiding stresses due
to load movements and enhancing appliance precision.
These assemblies are put together in our production
line and cannot be modified later by the user.
T 2026 GB
ind 04
06/09
1/2
Operating Principle
Strain gauge measurement of the extension, within its
limits of elasticity, of a metal body subjected to traction
stress.
The sensor generates an electrical signal that is proportional to the load. This signal is processed by a
micro-processor analyser and then transmitted via
radio waves to the display unit, which immediately displays the load applied to the sensor to which it is linked.
The display unit is compatible with all of the LLX 2
model sensors, irrespective of their capacity.
Technical Specisfications:
Precision: 0.1 % (ISO 376 . 21 °C)
Coefficient safety: minimum 4
Power supply: 3 x 1.5 V "AA" batteries. Removable
Display 1 x LI ONE battery (delivered with charger)
The standard version of the equipment comes with batteries and power pack in a carrying case.
Protection : IP 66, NEMA 4 (sensor)
More details are available on page 2.
Optional Accessories
PC connection Kit
Chain accessories with rapid connection
Connecting shackles
I.P. 67 Protection
Provisions applied :
Machine Directives : 98/37/CEE
European Standards : EN 12100-1 and 12100-2
CEM Directive : 89/336/CEE
Electrical Safety : IEC 61010-1 2de Edition 2001
Radio certifications : CE :Radio test EN 300 440-2 V1.1.1 / USA & Canada : FCC part 15 / Australia : C-Tick ID
R&TTE Directive (1999/5/CE)
0,5 / 1 / 2 / 3,2 t
5 / 6,3 t
®
®
10 t
Coplanar Version
®
®