News on energy efficiency0 pages
© 2011 KOMMUNIKATION SCHNELL GmbH
What must, what can be marked? What can be supplied in which design?
Standard
IEC 60034-30: 2008
Classification of
classes: IE1, IE2, IE3
EuP directive/
regulation 640/2009
Mandatory minimum
requirements
VEM
product range
1.
Standard three-phase asynchronous motor
0,75 – 375 kW
2,4,6 – pole, continuous duty S1
(note: is also valid if the motor is installed in
another machine)
yes
note: additionally duty
type S3 (=>80 % operational time)
yes
2.
Standard three-phase asynchronous motor
with auxiliary equipment (shaft seals, return
stops, encoder, separately driven fan, etc.)
0,75 – 375 kW, 2,4,6 – pole, continuous duty
S1 (note: measurement of efficiency without
auxiliary equipment)
yes
note: additionally duty
type S3 (=>80%
operational time)
yes
available in
IE1, IE2, IE3
3.
Gear motors, integral gear motors
yes
yes
available in
IE1, IE2, IE3
4.
Explosion-protected motors
yes
no
available in
IE1, IE2,
IE3 on request
5.
Water-cooled motors
yes
yes
available in
IE2, IE3
6.
Brake motors:
(A motor with an electro-mechanical brake
that interacts directly with the driving shaft
without coupling)
yes
no
available in
IE1, IE2, IE3
7.
Marine motors
yes
no
available in
IE1, IE2,
IE3 on request
8.
Roller table motors
(duty types S4, S7, S9)
no
no
available without
IE mark
9.
Non-ventilated motors (IC 410)
yes
no
available in
IE1, IE2,
10.
Compact drives
no
no
available with IE1- or
IE2 motor as basis
11.
Slip-ring motors
no
no
available without
IE mark
12.
Motors that are integrated completely in
another machine (i.e. pumps, fans (IC 418),
gears and compressors) so that the
efficiency of this motor can not be
determined separately;
no
no
available without
IE mark
Other motor types
(i.e. 8-pole and above and pole-changing
motors, motors < 0,75 kW and > 375 kW,
permanent magnet motors, motors for duty
types S2 – S10 and others)
no
Handling the new rules for efficiency classes
and minimum efficiencies of low voltage asynchronous
motors up to 375 kW
available in
IE1, IE2, IE3
13.
no
available without
IE mark
Europe
VEM motors GmbH
Carl-Friedrich-Gauss-Strasse 1
38855 Wernigerode
Germany
Phone:t+49 3943 68-0
Fax:t +49 3943 68-2440
e-mail: motors@vem-group.com
www.vem-group.com
VEM/03-179/E0111 Printed in the Federal Republic of Germany. Changes are reserved.