VP32 Series (VMECA Vacuum Switches)0 pages
ACCESSORIES
VACUUM Switch
Order No.
VP 32 V - 01 F1 - C □
①
②
③
④
⑤
④ Cable Specification
① Pressure Range
•
Nomark : Lead wire type (2M)
C - Compound (-100.0 ~ 100.0 kPa)
•
C : M8-4 Pin male connector
V - Negative (-101.3 ~ 0 kPa)
P - Positive (0.00 ~ 1.00 MPa)
② Output type
• 01 - 2 NPN Output
02 - 2 PNP Output
⑤ Analog output
Nomark : Without analog output
•
A : Analog output (1~5V)
※ for Analog type
01 : 1 NPN + 1Analog Output
03 : 1 PNP + 1Analog Output
③ Pressure Port
• F1 - PT1/8" male, M5 female
Option
• VCM8 4 2 : M8-4 pin female
connector
• Bracket D : Mounting bracket (BT 3 + BT 4)
2: 2M Lead wire
4: 4 Pin connector
• Bracket E : Mounting bracket (PA 3 + PA 4)
VCM8: M8-Female connector
• Bracket E : Panel adapter + Front protective lid
(PA 3 + PA 4 + FPC 2)
Operating Specifications
Specifications
Model
Fluid
Setting pressure range
Withstand pressure
-100.0 ~ 100.0 kPa
kPa
MPa
Indicator resolution
kgf/㎠
bar
psi
InHg
mmHg
Power supply voltage
Current consumption
Switch output
Environment
Analog output
Repeatabillity (Switch output)
Response time
Output short circuit protection
Indicator accuracy
One point set
Hysteresis
Hysteresis mode
Window mode
Enclosure
Ambient temp. range
Ambient humidity range
Vibration
Shock
Temperature characteristic
Port size
Lead wire
Weight
www.vmeca.com
VP32 C..
VP32 V..
VP32 P..
Air, Non-corrosive gases, incombustible gases
0.0 ~ -101.3 kPa
300 kPa
0.1
0.001
0.001
0.01
0.1
1
0.000 ~ 1.000 MPa
1.5 MPa
0.001
0.01
0.01
0.1
-
12~24 VDC±10%, Ripple (P-P) 10% or less
≤ 40 mA (with no load)
NPN open collector
Max. load currunt : 125mA
Max. supply volatage: 30VDC
Residual voltage : ≤ 1.5V (load currunt 125mA)
PNP open collector
Max. load currunt : 125mA
Max. supply volatage: 24VDC
Residual voltage : ≤ 1.5V (load currunt 125mA)
Output Voltage: 1~5V ≤ ±2.5%F.S.(within rated pressure range) Linearity : ≤±1% F.S. Output impedance : 1㏀
≤±0.2% F.S. ±1digit
≤2.5ms (chattering-proof function : 25ms,100ms, 250ms, 500ms, 1000ms, 1500ms selections)
Yes
≤±2% F.S ±1 digit (ambient temperature : 25±3℃)
Adjustable within 1~8 digits
Adjustable within 1~8 digits
Fixed (3 digits)
IP40
Operation : 0 ~ 50℃, Storage : -10 ~ 60℃ (No condensation or freezing)
Operation/ Storage: 35~85% RH (No condensation)
Total amplitude 1.5mm or 10G, 10Hz-150Hz-10Hz scan for 1 minute, hours each direction of X,Y and Z
1000 ㎨ (10G), 3 times each indirection of X,Y and Z
≤±2% F.S of detected pressure (25℃) at temp. range 0~50℃
PT 1/8" male, M5
F1: 1/8" PT, M5
Approx. 80g (with 2M lead wire), Approx. 45g (with male connector)
Specifications subject to change without notice
"