62NRM 2 Way Manifold Male0 pages
Model: 62NRM
nnnn2 VALVE INSTRUMENT MANIFOLD
nnnnREMOTE MOUNTING VERSION
nnnn@ Budenberg
nnnnThe 62NRM range of Two Valve Manifolds provide a low cost
nnnnBlock and Bleed function to any Instrument Installation or
nnnnapplication.
nnnnBased around the Budenberg 6N Needle Valve technology the
nnnnversatility of these manifolds enable Isolation, calibration and
nnnnventing within a single unit thereby eliminating potential leak
nnnnpaths. The 62NRM range Includes a full range of configurations
nnnnand connections allowing them to be used on a full range of
nnnnInstrumentation Including Transmitters, Gauges, Switches etc.
nnnnAll units Incorporate the Budenberg 6N high temperature, high
nnnnpressure valve head assembly that Is suitable for pressures up to
nnnn10,000 pslg and temperatures up to 450 Degree Celsius.
nnnnThese lightweight compact units can be readily manufactured,
nnnnmodified or configured to suit any Individual application or
nnnncustomer requirement.
nnnnBasic Models
nnnn62NRM- Male process X Female Instrument connections.
nnnnFor Direct transmitter mounting versions see additional datasheets
nnnnMaterial of Construction
nnnnStandard material Is 316 St St to NACE MR 01-75. Units can be
nnnnmanufactured In a range of wetted parts materials Including
nnnnMonel and Hastelloy
nnnnStandard Connection Sizes
nnnn1/2" NPT or BSPP Male process connection and female
nnnnInstrument connections, Vent connection Is 1/4" NPT or BSPP
nnnnFemale.
nnnnOther thread sizes available, contact sales for further details
nnnn6,000 pslg Cold Working Pressure designated 62Nx
nnnn10,000 pslg Cold Working Pressure designated 102Nx
nnnnOperating Temperature
nnnn-20 to 240°C maximum for units fitted with PTFE stem packing
nnnn-20 to 450°C maximum for units fitted with Grapholl packing
nnnnFor Cryogenic applications then a range of extended head versions are available
nnnnDust Cap Identification
nnnnWhite Dust Cap Indicates PTFE Stem Packing
nnnnBlack Dust Cap Indicates Graholl Stem Packing
nnnnFire safe
nnnnDesigned and Certified to BS 6755 Pt 2
nnnnNeedle Valve Features
nnnnStem Packing
nnnnFully adjustable, dynamically responsive, multi ring 'gland
nnnnsandwich' In either PTFE or Grapholl to resist all operating and
nnnnprocesses. Budenberg offer 100% gland Integrity for the lifetime
nnnnof every valve
nnnnStem Tip
nnnnSelf centring, non rotating stem tip provides a true metal to metal
nnnnvalve seat whereby the material of the stem tip Is one grade harder
nnnnthan the body thus resisting overtightening, preventing wear and
nnnnguaranteeing a 100% bubble tight seat closure, first time, every
nnnntime
nnnnAntl static, antl blow-out stems
nnnnTrue metal to metal Body / Bonnet joints. Bonnets are assembled
nnnnwith a bonnet locking pin to prevent accidental removal
nnnnPressure & Temperature ratings as ASME/ANSI B 16.34 Class 2500
nnnnT' Bar operator with torque break feature
nnnnCertification
nnnnMaterial Certification to EN 10204 3.1b Ine Mill Certificates
nnnnPressure Test Certificate
nnnnCE Certificate of Conformity
nnnnOther testing / documentation / certification can be supplied
nnnndependant upon the contract / project requirements.
nnnnRev-01 Jan 2007
nnnnDesigned and Manufactured In UK.
nnnnDatasheet VAC-20
"