Compression, Compact0 pages
Compression Weighing Load Cells
Capacities: 50,000 lb/22,680 kg,
100,000 lb/45,360 kg,
120,000 lb/54,430 kg
• Environmentally-sealed (IP68)
• Stainless steel construction
• 35'/10m integral shielded cable
• 2-year warranty
These heavy-capacity compression load cells
are ideal for multi-cell applications including
truck scales, railroad track scales, and heavy-duty
tank/hopper weighing systems.
MECHANICAL DATA
Rated Capacity,
(R.C.) Emax
50,000 lb / 22,680 kg, 100,000 lb /
45,360 kg, 120,000 lb / 54,430 kg
Minimum Dead
Load
500 lb / 226 kg, 1,000 lb / 454 kg
1,200 lb / 544 kg
Safe Load Limit
150% R.C.
Ultimate Load
The SCA load cells are fabricated from stainless steel
to provide the ultimate in protection when caustic,
corrosive or wet environments are encountered.
Load cells are environmentally-sealed
for absolute water protection. Each load cell is furnished with stainless steel load buttons on
each end, and an integral multi-conductor
cable secured by a strain relief seal.
CERTIFICATE DATA
ISSUING BODY
NTEP
OIML
89-042A4
R60/1991DK-97.04 rev 1
IIIL
C3
10,000
3,000
300% R.C.
Deection at R.C.
Net Weight
Certicate Number
Accuracy Class
0.01 in / 0.33 mm
50K-SCA: 13 lb / 5.8 kg
100K-SCA: 10 lb / 4.8 kg
120K-SCA: 11 lb / 5 kg
ELECTRICAL DATA
Rated Output
2mV/V
Excitation Voltage, Minimum
Single/Multiple
M
Humidity Symbol
Minimum Load Cell
Verication Interval Vmin
10 VDC
Excitation Voltage, Maximum
Maximum Number of
Load Cell Intervals, nmax
CH
1.5 lb/0.68
kg, 3 lb/1.36
kg, 3.6
lb/1.63 kg
1 lb/0.45 kg,
2 lb/0.9 kg,
2.4 lb/1.09 kg
15 VDC
Cable Length
Terminal Resistance
Excitation
Signal
Zero Load Output
Insulation Resistance
35 ft / 10 m
1,150 ± 60 ohms
1,050 ± 15 ohms
>2% R.C.
>5,000 megohms
at 50 VDC
ENVIRONMENTAL DATA
Temperature Compensation Range
-10 to +40˚C
Operating Temperature Range
-29 to +93˚C
Construction & Protection Code
CP-67 HU, IP68
Barometric Pressure Effect on
Zero Load Output
<1 v (min)/1kPa
MADE IN USA
Bulletin No. 263-6D
LOAD CELLS
SCA Series
"