C-GRID: C25-Ox2.30 pages
Technical Data Sheet
April 2010
C25 – ø x 2.3
Carbon Fiber Reinforcing Grids for Concrete Structures
DESCRIPTION C-GRID® C25 – ø x 2.3 is one of the C25 Series of high strength carbon fiber/epoxy grids for reinforcing concrete structures.
Large high strength carbon strands are aligned only in the transverse direction.
Features
Applications
Non-corrosive; can be used with as little as
1⁄4” (6 mm) of cover
Slabs-on-grade
Requires less concrete cover leading to
lighter structures
Marine structures
Thin topping slabs and overlays
Lightweight, easy to handle and use; can be
cut to fit using conventional tin snips
Silos and concrete storage tanks
High tensile strength and modulus
Balconies
Outstanding mechanical bond with concrete;
requires a mimimum 1⁄4” (6 mm) to develop
its strength
Precast concrete, including architectural
and wall panels
Concrete repair and shotcrete
PHYSICAL PROPERTIES
carbon fiber with glass fiber support and epoxy resin
Color
black
Grid geometry (longitudinal x transverse spacing)
ø x 2.3” (ø mm x 58.4 mm)
Supply form (custom widths and lengths also available)
76” x 600 yd (1.93 m x 548.6 m) rolls
TYPICAL MECHANICAL PROPERTIES
TRANSVERSE PROPERTIES
0.001430 in2
(0.92 mm2)
Average number of strands per unit width
5.22 strands/ft
(17.12 strands/m)
Area of strands per unit width
0.007461 in /ft
(15.79 mm2/m)
465 lbs
(2.07 kN)
Grid tensile strength per unit width
2.43 kips/ft
(735.4 kN/m)
Tensile modulus of elasticity
34,000 ksi
(234,500 MPa)
0.94%
(0.94%)
Individual strand cross-sectional area
Strand tensile strength
Elongation at break
2
Application Use Note: C-GRID® remains a relatively novel material without the extensive performance history of traditional construction materials. Reported properties are average values, not design values. Structures and applications
using C-GRID® should be designed using appropriate safety factors or load and strength reduction factors. All applications utilizing C-GRID®, including critical life safety and fire rated structures, should be designed and reviewed by a
licensed engineer experienced with FRP materials. The data expressed herein is believed to be accurate at the time of publication; however, it is subject to change without notice.
1.t
2.t
3.t
4.t
Notes:
Centerline-to-centerline spacing between strands is nominal and based on the average number of strands per unit width. Actual spacing may vary by ± 0.10” (± 2.5mm).
The longitudinal direction is in the direction of the roll, and the transverse direction is across the width of the roll. For example, if a roll of C-GRID® is 47.5” wide, the carbon strands in the transverse direction are 47.5” in length. If
a roll of C-GRID® is 500 yards long, the longitudinal strands are 500 yards in length.
Individual strand cross-sectional area is normalized to the cross-sectional area of the fibers in accordance with ACI 440.2R. The actual measured thickness and width are larger and shall not be used for design purposes.
Reported tensile strengths are typical or average properties based on testing. Tensile modulus values are based on properties reported by the carbon fiber supplier. C-GRID® exhibits linear elastic behavior, so failure strains are
estimated using Hooke’s Law.
Chomarat North America
2901 New Pond Road
Anderson, SC 29624 - USA
+ 1 864 328 1700 tel.
+ 1 864 260 3364 fax
info@chomarat.com
www.chomarat.com
C-GRID® C25 – ø x 2.3 Carbon Fiber Reinforcing Grid
"