section 160 pages
Table of Contents/Introduction
Quick Reference
Index
Cartridge Valves Technical Information
Directional Valves DCV 03
9
8
2
6
7
4
1
5
3
9
8
Directional control valves
DCV03
OVERVIEW
4
P104 435E
DCV 03 directional control valves consist of: housing (1), control spool (5), with two
centering springs (4), and cylindrical operating solenoids (2, 3).
The three-position directional valves have two solenoids and two springs. Two-position
directional valves have either one solenoid and one return spring or two solenoids and a
detent assembly.
The operating solenoids are DC. For AC supply the solenoids are provided with a rectifier,
which is integrated directly into the coil.
The plug connectors (6, 7) can be rotated 90°. By loosening the nut (8), the solenoids can
be rotated 360°. This enables the solenoids to be replaced without opening the valves.
In the case of solenoid malfunction or power failure, the spool can be actuated by
manual override (9), provided the pressure in T-port does not exceed 25 bar [360 psi].
The valve housing (1) is phosphate coated. The operating solenoids (2, 3) are zinc coated.
FEATURES
•t
3 position, 4-way, and 2 position, 4way directional valves
•t
Cylindrical operating solenoids with
separate operating coils – connector
can be rotated 90°
•t
4-land spool – reduced functional
dependence on fluid viscosity
•t
Push button manual override
•t
Installation dimensions to ISO 440103-02-0-94 and DIN 24340-A6
520L0588 • Rev DB • November 2010
16.1
"