LR-Cal PULSAR-80Cu0 pages
Portable Temperature Calibrator
Dry block calibrator up to +550°C
PULSAR-80CU
Dry block Temperature Calibrator Type PULSAR-80CU
C Temperature range: ambient temperature up to +550°C
C For mobile and stationary use
C Micro processor operated, ramp function, thermostat tests
Typical applications:
C Calibration and checking of all kinds of thermometer
C Calibration and checking of thermostats
C Computer aided calibration via RS232 interface
Technical Data PULSAR-80CU:
Order-Code: PULSAR-80CU
Temperature range: ambient temperature up to +550°C.
Display resolution: 0,01 / 0.1°C (unit switchable to °F or K)
Stability: ±0.5°C (at 450°C)
Mean heating time: 9°C per minute
Mean cooling time: 1.6°C per minute
Display accuracy: ±0.3°C at 450°C
Integrated reference sensor: resistance thermometer 3-wire
Ventilation: integrated, electronic operated.
Interface: RS232 (9-pol. D-sub)
Ramp function: min. 0.1°C per minute
Dry block: diam. 60 mm. made in copper-alloy.
Test well depth: 275 mm, 1 insert
Optional: insert with holes as per customers request (if possible) or without holes.
Power supply (50/60 Hz): 230 VAC (optional: 115 VAC)
Power consumption: 1700 VA
Case material: metal
Dimension: 160 x 340 x 330 mm, Weight: 23 kg net
NOTE: The stated accuracy is valid at ambient temperature +10°C...+40°C and is guaranteed
for 1 year.
In addition, at type PULSAR-80CU-2I: Order-Code: PULSAR-80CU-2I
Two inputs for Pt100 and thermocouples, programmable.
• Pt 100 IEC 3-/4-wire, range -100/+700°C, accuracy ±0.3°C
• Thermocouple type J, range 0-1000°C, accuracy ±1°C
• Thermocouple types K/N/R/S, range 0-1300°C, accuracy ±1°C
Scope of standard supply:
Dry block calibrator PULSAR-80CU, electrical connection cable, spare fuses, cable for thermostat tests, operating manual, certificate
of calibration (traceable), tool for insert removing.
1 insert with 4 holes 4.5 - 6.5 - 9.5 - 12.5 mm). At type PULSAR-80CU-2I set of measuring cables with 4 mm plugs.
Optional Accessories:
• Insert with holes as per customers request (if possible)
• Insert without drilling
• Aluminum carrying case
• RS232 cable and PC-Windows-Software AQ2sp
The PULSAR-80CU can operate in automatic mode connected to
a PC by means of the optional AQ2sp software which enables
to carry out probe calibrations and cyclical life tests; test results
can be stored and printed, so they are easily traceable in
compliance with ISO 9000 standards.