LT LED Linear Outlets Lighting data sheet0 pages
LT - 2012.07.05
FKK Corporation
FKK Corporation
LED LINEAR COVE LIGHTING LT
Under Cabinet / Cove Lighting
11 Tsutsumisoto-cho Kisshoin Minami-ku,
601-8399 Kyoto, JAPAN
TEL+81(0)90 5364 7527
URLwww.fkk-corporation.com
Manual
Safety Cautions
21 16.6
S p e c i fi c a t i o n
Fixing srew hole ø5
15
16.8
15
37.6
Length
Polycarbonate cover - Lighting part
A
Risk of fie, electrical shock or injury. Observe the following instructions
when installing this product.
Use this unit only in the manner intended by the manufacturer.
If you have any questions, contact us.
B
Do not put display products too close to the fixture while power is
switch on
This fixture is for indoor use only. Please do not use in the following
environments.
· Outdoor and high temperature environment (more than +40 ℃).
Normal operating temperature : 5 to +40 ℃
• High humidity (85%) environment
• Excessive amount of dust or corrosive gas environment
• Flammable gases environment
• Airtight environment
• Environment exposed to water splash
• Environment directly exposed to sea water or organic solvents
• Environment exposed to direct sunlight
• Environment exposed to high magnetic flux
• Environment exposed to vibrations
• Unstable environment
Please do not use infrared remote control device in the vicinity of the
fixture, it may cause malfunction.
Wire holder case
A
Sliding hook mounting
Polycarbonate
hole
Sliding bracket
B
Aluminium body
Aluminium
body
LED light engine
LED driver case
Wire holder
Polycarbonate cover
50.5
Open/closed case
Before installing, servicing or cleaning unit, switch power off at the service
panel and follow appropriate lock out/tag out safety procedures.
37.6
Enlarged side view
A-A Enlarged cross
sectional view
B-B Enlarged cross
sectional view
Do not use in wet locations.
Unit (mm)
Rail mounting bracket
Sliding hook
This device must be supplied with 240V AC/50Hz and connected to an
individual properly grounded branch circuit, protected by a 15 ampere
circuit breaker.
Use it to mount the fixture on slide rail or mounting bracket.
A: OBH-L Mounting bracket and rail set 1400 JPY
B: ATC-L Mounting rail only 580 JPY
Use it to mount the fixture on sliding hooks
SLD-L (Chrome) 960 JPY
Maximum sliding size 60mm
Electrical connection of leader cable(s) to 240 V AC must be prepared by a
trained, qualified pesonnel following all applicable national regulations.
Accesories
Risk of damage to unit. Do not use 120 V AC fixtue in a 240 V AC circuit.
Risk of electrical shock. Disconnect power before install.
Light Intensity distribution
Photometric data
Measured fixture:
LT-900-D
(Daylight 6500K)
Face of the shelf
Drawing
Candlepower Distribution
Bottom of the shelf
Wire holder case
180
150
250
150
200
1
165
150
120
Risk of electric shock or damage to unit. Do not use fixture with
broken cover.
120
100
26° 36°
Risk of electric shock or damage to unit. Please do not put metal parts
in the fixture.
Please do not attempt to do the following to the fixture:
· Peeled off after installation
· Disassemble or modify, such as drilling hole
· Force-pulling, twisting
• Cut or scratche the power supply cable
• Use damaged power supply cable
• Drop it, hold down
• Apply severe vibration or impact
50
2
47
90
Risk of electric shock or damage to unit. To clean the fixture, please
use a dry cloth. Do not use water, benzene or organic solvent to clean.
90
0
22
1000 3
500
200
100
4
50
20
14
Unit (lx)
3m
Specification
2
1
0
1
2
60
60
30
30
cd/(1000)lm
0
3
AC 220-240V specifications
Accesories:
Reference
Length
(mm)
Weight
(kg)
Number of
LED
Watts
(W)
Amps
(A)
Maximum length Luminous flux
(lamps)
(lm)
LT-300
280
0.14
24
2.3
0.01
100
140
LT-500
480
0.24
54
4.5
0.02
50
320
LT-600
570
0.29
72
6.7
0.03
32
435
LT-750
720
0.36
90
7.8
0.04
28
870
0.43
108
9.3
0.05
22
635
Sliding hook SLD-L(Chrome)
・OBH-LMounting bracket and rail set
・ATC-LMounting rail only
・Power supply leader cable LDG・LDGP
・Jumper cable LWR
・Electrical outlet cable CPS
L=Light bulb (2700K)
WW=Light bulb (3500K)
W=White (4200)
N=Neutral White (5000K)
D=Daylight (6500K)
530
LT-900
LED colors:
LT-1200
1170
0.58
144
13.3
0.07
16
815
LT-1500
1470
0.74
192
17.1
0.09
12
1130
LT-1800
1770
0.89
240
20.6
0.11
10
BEFORE YOU BEGIN : Read these instructions completely and carefully.
Electrical connection of leader cable(s) to 240 V AC must be prepared by a trained, qualified pesonnel following all applicable national regulations.
Plese use specified power supply cable (sold separately) and follow installation manual before switch power supply on.
Environment of useIndoor only
Operating conditionTemperature 5℃to +0℃ / Humidity below 85
Standard compliancePSE, CE (in process)
1415
50/60Hz Frequency. Protection: built-in sruge protection, ESD protection. Concerning maximum length of connection, if you want to connect together fixtures of dierent length, please do it within 1 Amps.
Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

عضویت
ورود اعضا
راهنمای خرید