THE Pump Model0 pages
Bulletin 07-01-212
nnnnVersion 2
nnnnModel THE
nnnnHORIZONTAL DRILLING DUTY PUMP
nnnnSPECIFICATIONS:
nnnnMaximum BHP: 215 (160 kw)
nnnnMaximum RPM: 300
nnnnNo. of Plungers: 3
nnnnStroke Length: 5 in. (127 mm)
nnnnPlunger Load: 37,000 lbs. (16,965 kg)
nnnnDischarge Hydrostatic Test Pressure
nnnn3,600 psi (1,633 kg/cm2)
nnnnOil Capacity: 12 gal. (45 liters)
nnnnPump Weight: 3,990 lbs. (1,810 kg)
nnnnPERFORMANCE RATINGS
nnnnPiston/Liner Size | Displacement per Revolution | Displacement at Pump RPM | |||||||||||||
50 | 100 | 150 | |||||||||||||
in. | mm | GPR | LPR | GPM | LPM | PSI | kg/cm2 | GPM | LPM | PSI | kg/cm2 | GPM | LPM | PSI | kg/cm2 |
5" Cast Fluid End | |||||||||||||||
4 | 102 | 0.816 | 3.089 | 41 | 154 | 2944 | 206 | 82 | 309 | 2944 | 206 | 122 | 463 | 2718 | 191 |
4.5 | 114 | 1.032 | 3.907 | 52 | 195 | 2326 | 163 | 103 | 391 | 2326 | 163 | 155 | 588 | 2100 | 148 |
5 | 127 | 1.274 | 4.824 | 64 | 241 | 1884 | 132 | 127 | 482 | 1884 | 132 | 191 | 724 | 1700 | 120 |
5.5 | 140 | 1.542 | 5.837 | 77 | 292 | 1557 | 109 | 154 | 584 | 1557 | 109 | 231 | 876 | 1435 | 100 |
Input Power: | BHP | 79 | 156 | 215 | |||||||||||
kW | 59 | 116 | 160 | ||||||||||||
Piston/Liner Size | Displacement per Revolution | Displacement at Pump RPM | |||||||||||||
200 | 250 | 300 | |||||||||||||
in. | mm | GPR | LPR | GPM | LPM | PSI | kg/cm2 | GPM | LPM | PSI | kg/cm2 | GPM | LPM | PSI | kg/cm2 |
5" Cast Fluid End | |||||||||||||||
4 | 102 | .816 | 3.089 | 163 | 618 | 2034 | 143 | 204 | 772 | 1625 | 114 | 245 | 927 | 1354 | 95 |
4.5 | 114 | 1.032 | 3.907 | 206 | 781 | 1600 | 112 | 258 | 977 | 1280 | 90 | 310 | 1173 | 1070 | 75 |
5 | 127 | 1.274 | 4.824 | 255 | 965 | 1300 | 91 | 319 | 1206 | 1040 | 73 | 383 | 1448 | 870 | 61 |
5.5 | 140 | 1.542 | 5.837 | 308 | 1167 | 1076 | 76 | 386 | 1460 | 860 | 60 | 462 | 1752 | 720 | 51 |
Input Power: | BHP | 215 | 215 | 215 | |||||||||||
kW | 160 | 160 | 160 |
A lubrication system supplying oil at 50 psi, 12 gpm and 200 SUS (44cSt) minimum values is required. Oil cooling is recommended and may be required to
nnnnmaintain these values.
nnnnFor operation in the Yellow shaded area expendable part life decreases and excellent NPSH is required to prevent cavitation.
nnnnPerformance figures based on 100% volumetric efficiency and 90% mechanical efficiency. These figures are for use in directional drilling duty cycle.
nnnn"This equals full rod load 33% of the time, 60% rod load 50% of the time and 25% rod load 17% of the time, for a total of 1456 hours per year.
"