EDW_EDX_9000 pages
mmiiMimmm
000] - Weather Proof Type
- Explosion Proof Type
The NEW-FLOW Displacer Level Indicator are made to fit wide range ap-
plications such as pump control, waste water level and deep open tank.
They are designed for high corrosive resistance and long service life.
900-Series are switch setting available and provide output signals 4~20mA.
Technical Data
Material: Aluminum alloy case with paint; SS316 available
Body & Wetted Parts Material: SS316L, Indication via magnetic coupling (no sealed)
Scales Calibrated: in % or height
Range of Measurement: 300mm to 5M available; option on request
Connection Types: Flange type, Trip Clamp & Sanitary; Thread type (others on request)
Connection Size: lVz"~A"
Process Connection Rating: Thread type: NPT, BSP; Flange type: ANSI, DIN, JIS available
Max. Working Temperature: -50°C to +150°C (300°C option)
Max. Working Pressure: up to lOOBar; option on request
Protection Class: IP66 or Explosion Proof, Class I, Groups B, C & D;
Class II, Groups E, F & G; NEMA 4, 7, 9
Accuracy: ±2% F.S (±1.6% F.S option)
Conduit Connection: Female V^'NPT, V2"BSP, WNPT, WBSP; option on request
Option: GS-M: adjustable Micro Switch (5A/250VAC, 2A/30VDC);
GS-R: adjustalbe Reed Alarm Switch (form A bistaqble type, N.O. type);
GS-C: adjustable Inductive alarm Switch;
GT: analog output 4~20mA, 2-wires
*HART® Communication: available
Two Wires Transmitter with HART® Protocol
- Galvanic Isolation
- Suitable for application in SIL2 installations
HAJRTFVV
Housing Type
IP66 Rectangle Bolt Tight Type
Case Type: (A-l)
Housing Material:
Alunimum alloy case with paint
IP66 Round Screw Tight Type
Case Type: (A-2)
Housing Material: Aluminum alloy
Case Type: (B) Round Screw Tight Type
Housing Mat rial: SS316
Explosion Proof
Case Type: (c)
Class I, Groups B,C & D;
Class II, Groups E,F & G;
NEMA 4,7,9
"Mounting length: 250mm standard
Connection size bigger than 3", mounting length is 300mm.
"