AM4X0 pages
Maintain Optimal Firetube Boiler Efficiency
Don’t let heavy scale and deposits wreak havoc on your system’s performance.
RAM-4X and RAM-4X2A – Turbine Action
It doesn’t take long for heavy build-up of scale and soot to form in firetube
boilers. That’s why it’s imperative to thoroughly and frequently clear your
system of contaminants that can cause drastic increases in wasteful fuel
consumption. Both the RAM-4X and the RAM-4X2A use the same trusted
technology as the popular RAM-4 unit to clear larger I.D. boiler tubes.
Powerful turbine action does the dirty work. With a variety of brushes and
cleaning tools to choose from, these units make any boiler-cleaning operation
an easy, one-person job that pays dividends in increased efficiency.
Boiler Cleaning Systems (No Vacuums):
RAM-4X-60
Firetube Boiler Cleaner, including mobile dolly, tool storage box
and foot switch
FEATURES
> Stainless steel construction
> Interchangeable cleaning tools
> Integrated dolly
> Simultaneous water flush or vacuum
> Foot switch activation
Specifications
Motor Power
Input Power
Power Supply Cord
Flexible Shaft Speed
Water Requirements
Dimensions
Weight
Specifications
Motor Power
Input Power
Power Supply Cord
Flexible Shaft Speed
Water Requirements
Dimensions
Weight
RAM-4X
1 HP
Standard: 13 amps, 115 V, 60 Hz AC
Optional: 13 amps, 115 V, 50 Hz;
6.5 amps, 230 V, 60 Hz; or
6.5 amps, 230 V, 50 Hz
21', 14-3 GFCI
1,725 rpm (can be decreased to
862.5 rpm by changing pulley ratio –
request 2:1 ratio drive for greater torque)
Minimum 30 PSI at 3 GPM
37" high x 20" wide x 17" deep
59 lbs
RAM-4X2A
2 HP
Standard: 11.5 amps, 230 V, 60 Hz AC
Optional: 11.5 amps, 230 V, 50 Hz
21', 14-3 GFCI
1,725 rpm (can be decreased to
862.5 rpm by changing pulley ratio –
request 2:1 ratio drive for greater torque)
Minimum 30 PSI at 3 GPM
37" high x 20" wide x 17" deep
75 lbs
RAM-4X2A-60
Firetube Boiler Cleaner, including mobile dolly, tool storage box
and foot switch
Note: Call for shafts and accessories.
Note: Call for nozzle and brush sizes.