501/414 Cable Gland0 pages
Cable Glands
501/414
Hazardous Area
90
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Application
15.0mm 'G' Approx (Fully Compressed Length)
Female Entry
Thread
Ø 'B'
Male
Entry Thread
Metric
Entry
• Outdoor or indoor use.
• For use with non-armoured elastomer and plastic insulated cables installed
in conduit.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Female Entry Thread Size
Cable Acceptance Details
Outer Sheath 'B'
NPT *
NPT #
Standard Seal
Alternative Seal (S)
Standard or
Metric
Standard or
Option
Option
Min.
Max.
Min.
Max.
Male Entry Thread Size
Size
Ref.
Metric
Os
O
A
B
C
C2
D
E
F
M20²
M20²
M20
M25
M32
M40
M50
M63
M75
½"
½"
¾" or ½"
1" or ¾"
1¼" or 1"
11⁄2" or 11⁄4"
2" or 11⁄2"
21⁄2" or 2"
3" or 21⁄2"
M20
M20
M20
M25
M32
M40
M50
M63
M75
-
3.0
7.5
11.0
13.0
19.0
25.0
31.5
42.5
54.5
8.0
11.9
14.3
20.2
26.5
32.5
4.4/42.31
56.3/54.31
68.2/65.31
8.5
9.5
15.5
22.0
27.5
39.0
48.5
13.4
15.4
21.2
28.0
34.8
46.5
58.3
Hexagon Dimensions
'G'
Across
Flats
Across
Corners
54.5
54.5
56.4
48.2
61.6
64.6
83.2
83.2
86.4
24.0
24.0
30.0
36.0
46.0
55.0
65.0
80.0
95.0
26.5
26.5
32.5
39.5
50.5
60.6
70.8
88.0
104.0
All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard.
¹ Smaller value is applicable when selecting reduced NPT male entry option.
² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter.
Technical Data
• Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21.
• Certificate No’s: Baseefa06ATEX0056X and IECEx BAS 06.0013X.
• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas
Groups IIA, IIB and IIC.
• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1,
IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
• Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to
IEC/EN 60529 and NEMA 4X.
• Deluge Protection to DTS01.
• Operating Temperature Range: -60°C to +100°C.
• Assembly Instruction Sheet: AI 310.
• Alternative certification options available:
Exe II
Features
• Provides a cable retention seal onto the cables outer sheath.
• When used in Increased Safety applications, this cable gland may
•
•
•
be used with braided cable where the braid and the cables outer
sheath pass into the enclosure. The braid must be suitably
terminated into the enclosure.
Provides female running coupler for cable gland or conduit entry.
Manufactured in Brass (standard), Nickel Plated Brass,
316 Stainless Steel or Aluminium.
Brass NPT entries are nickel plated as standard.
Exd IIC / Exe II
GOST R-Exe IIU
GOST K- Approved for use in Kazakhstan
Ordering Information
Format for ordering is as follows: Alternative Seal (S), add suffix S to ordering information.
Cable Gland Type
501/414
Size
C
Thread
M32
(OPTIONAL)
S
Cable Gland Type
501/414
Size
C
Thread
1 1⁄4"NPT
(OPTIONAL)
S
Connection Solutions
www.ehawke.com
HPG01
UPD 090610