TGM Series Toroidal Grating Monochromators0 pages
TGM Specifications
TGM300
TGM1200
Optical design
TGM1900
Toroidal VLS Grating (single optic)
Focal length
320 mm
1000 mm
1146 mm
f/16
Aperture
f/32
f/34
Optic coating
Pt or Au
Deviation angle
142°
146°
Drive
150°
TGM-Series
Sine arm
Vacuum
10-6 mbar (HV version) or 10-9 mbar (UHV version)
Pumping flange
DN40 KF
DN100 LF
Entrance/exit port
DN100 LF
Micrometric slits (10 µm to 2 mm)
Entrance/exit
flange
Toroidal Grating Monochromators
DN40 KF
Software
HORIBA Scientific software
PC Interface
Coming from Synchrotron technologies
347.5
483
567.6
RS232 - USB2
OUT
224
IN
142°
420
730
376
218
540
622.5
523.5
TGM300 in UHV version, single grating configuration
IN
146°
OUT
2205
OUT
420
IN
232
378
525
2360
150°
TGM1900 in HV version, with two gratings in slider, custom version without entrance slit and arm
www.horiba.com/scientific
info.sci@horiba.com
France:t HORIBA Jobin Yvon S.A.S., 16-18 rue du Canal, 91165 Longjumeau cedex - Tel: +33 (0)1 69 74 72 00 - Fax: +33 (0)1 69 09 07 21 - Email: info-sci.fr@horiba.com
USA:t
HORIBA Instruments Inc., 3880 Park Avenue, Edison, NJ 08820-3012 - Toll-free: +1-866-562-4698 - Tel: +1 732 494 8660 - Fax: +1 732 549 5125 - Email: info-sci.us@horiba.com
Japan:t
HORIBA Ltd., Tokyo Branch Office, 2-6, KandaAwaji-cho, Chiyoda-ku, Tokyo 101-0063, Japan - Tel: +81-(0)3 6206 4721 - Fax: +81 (0)3 6206 4730 - Email: info-sci.jp@horiba.com
Germany:t HORIBA Jobin Yvon GmbH, Hauptstrasse 1, 82008 Unterhaching - Tel: +49 (0)89 4623 17-0 - Fax: +49 (0)89 4623 17-99 - Email: info-sci.de@horiba.com
Italy:t
HORIBA Jobin Yvon Srl., Via Cesare Pavese 21, 20090 Opera (Milano) - Tel: +39 2 5760 3050 - Fax: +39 2 5760 0876 - Email: info-sci.it@horiba.com
UK:t
HORIBA UK Ltd., 2 Dalston Gardens, Stanmore, Middlesex HA7 1BQ - Tel: +44 (0)20 8204 8142 - Fax: +44 (0)20 8204 6142 - Email: info-sci.uk@horiba.com
China:t
HORIBA (China) Trading Co. Ltd., Unit D 1F, Bldg A, Srynnex International Park, No. 1068 West Tianshan Road, Shanghai 200335 - Tel: +86 (0)21 6289 6060 - Fax: +86 (0)21 6289 5553
t
Email: info-sci.cn@horiba.com
Brazil:t
HORIBA Instruments Brasil Ltda., Rua Presbítero Plínio Alves de Souza, 645, Loteamento Polo Multivias, Bairro Medeiros, Jundiaí / SP, CEP 13.212-181 - Tel: +55 (0)11 2923 5400
Fax: +55 (0)11 2923 5490 - Email: infocientifica.br@horiba.com
Other:t
Tel: +33 (0)1 69 74 72 00 - Email: info.sci@horiba.com
Explore the future
Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific
This document is not contractually binding under any circumstances - Printed in France - ©HORIBA Jobin Yvon 06/2014
TGM1200 in HV version, with a two gratings in slider
Tunable light source
Synchrotron
compatible
High throughput
tAberration
corrected VLS
gratings
High Resolution
Explore the future
EUV spectroscopy
Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific
"