ACD 50ER-Series0 pages
ACD50ER_Datasheet table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:12.00pt "Arial", sans-serif; } .font5 { font:13.00pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } .font7 { font:5.00pt "Georgia", serif; } AC/DC - Converter 19"Eurostandard Օ EMI Compliant Design 3 U/8 HP/160 mm Օ Wide Range Input 90 ... 264 Vac Dual Output 50 Watt Օ All outputs galvanical insulated Technical Specification ACD 50ER-SerU Input Input range Vm: 90 ... 264 Vac / 47 .... 63 Hz Hold-Up Time @ Vin = Vmmm, Ltnom > 50 ms @ Vin = 187 Vac and full load Efficiency > 70 %, device dependant Input Protection varistor and non-resettable fuse 1AT/250V Output Ouput Voltages Vo see table at the end of the document Output Voltage Tolerance Vo1: +/- 5 % Vomom (Nominal value Vo1); fix adjusted Output Currents Io see table at the end of the document Ripple + Spikes, Measurement Bandwidth 20Mhz < 50mVpp + 0.5 % Vonom - all outputs Short Circuit Protection Yes; internal current limiting Overvoltage Protection Yes, at 5 V-output Line Regulation (Vinmin ... Vinmax) Vo1: < 0.2 % Vonom;, Io = constant Vo2: < 4 % Vonom, Io1_min = 10 % Load Regulation (10 % ... 90 % Io) Vo1: < 0.2 % Vonom;, Vin= constant Vo2: < 4 % Vonom, Io1_min = 10 % Temperature Coefficient < 0.02% Vo / K Settling Time (10...90 % Ut); di / dt = 1A/usec V01: < 0.02 % Vo / K Under/Overshoot for Pulsed Load < 5 % Vonom Page 1/3
"