KeDrive Power Units0 pages
KeDrive D6 – Inverter, Power Units
Models
no additional options
Performance data
- Continuous current ¹
- Maximum current
Single-axis inverters
HMS01.1N- HMS01.1N- HMS01.1N- HMS01.1N- HMS01.1N- HMS01.1N- HMS01.1N- HMS01.1NW0020A- W0036-A- W0054-A- W0070-A- W0110-A- W0150-A- W0210-A- W0350-A07-NNNN 07-NNNN 07-NNNN 07-NNNN 07-NNNN 07-NNNN 07-NNNN 07-NNNN
12,1 A
20 A
21,3 A
36 A
35 A
54 A
10 W
15 W
10 W
16 W
34 W
23 W
75 W
218 W
0,4 A
0,7 A
0,4 A
0,7 A
1,4 A
1,0 A
3,1 A
9,1 A
440 mm
50 mm
309 mm
5,3 kg
440 mm
50 mm
309 mm
5,3 kg
440 mm
75 mm
309 mm
6,7 kg
440 mm
100 mm
309 mm
7,9 kg
440 mm
125 mm
309 mm
11,0 kg
440 mm
150 mm
309 mm
12,7 kg
440 mm
200 mm
309 mm
18,4 kg
440 mm
350 mm
309 mm
31,7 kg
Switching frequency/max. output
frequency
Control voltage data
- Control voltage external
- Power consumption without
control unit and motor brake
- Continuous current without
control unit and motor brake
Mechanical data
- Height H
- Width W
- Depth D
- Mass
Ambient conditions
- Ambient temperature
- Relative air humidity
- Degree of contamination
- Cooling system
- Protection mode
Installation height
CE-mark
Certification
EMC
Models
no additional options
Performance data
- Continuous current ¹
-Maximum current
Switching frequency/max. output
frequency
Control voltage data
- Control voltage external
- Power consumption without
control unit and motor brake
- Continuous current without
control unit and motor brake
Mechanical data
- Height H
- Width W
- Depth D
- Mass
Ambient conditions
- Ambient temperature
- Relative air humidity
- Degree of contamination
- Cooling system
- Protection mode
Installation height
CE-mark
Certification
EMC
42,4 A
68,5 A
70 A
110 A
4 kHz / 400 Hz
8 kHz / 800 Hz
12 kHz / 1.200 Hz
16 kHz / 1.600 Hz
150 A
210 A
250 A
350 A
DC 24 V ± 20 % (DC 24 V ± 5 % when supplying motor holding brake)
0 ... +40 °C, with derating to +55 °C
5 ... 95 % (as per EN 61800-5-1), condensation not permitted
2 (as per EN 61800-5-1)
Air cooling
IP20
1.000 m over NN, with derating to 4.000 m
Complies with the low voltage directive 73/23/EEC and the EMC directive 89/336/EEC
UL, cUL
as EN 61800-3
Single-axis inverters
Double-axis inverters
HMS02.1NHMS02.1NHMD01.1N- HMD01.1N- HMD01.1NW0028-A-07- W0054-A-07- W0012-A-07- W0020-A-07- W0036-A-07NNNN
NNNN
NNNN
NNNN
NNNN
13,8 A
28 A
-
25 A
54 A
7A
12 A
4 kHz / 400 Hz
8 kHz / 800 Hz
12 kHz / 1.200 Hz
16 kHz / 1.600 Hz
10 A
20 A
20 A
36 A
-
DC 24 V ± 20 % (DC 24 V ± 5 % when supplying motor holding brake)
13 W
17 W
17 W
17 W
11 W
0,5 A
0,7 A
0,7 A
0,7 A
0,5 A
352 mm
50 mm
252 mm
3,5 kg
352 mm
75 mm
252 mm
5,0 kg
440 mm
50 mm
309 mm
5,5 kg
440 mm
50 mm
309 mm
5,7 kg
440 mm
75 mm
309 mm
7,5 kg
0 ... +40 °C, with derating to +55 °C
5 ... 95 % (as per EN 61800-5-1), condensation not permitted
2 (as per EN 61800-5-1)
Air cooling
IP20
1.000 m over NN, with derating to 4.000 m
Complies with the low voltage directive 73/23/EEC and the EMC directive 89/336/EEC
UL, cUL
as EN 61800-3
All data apply to nominal rating at 3 AC 400 V mains voltage and 4 kHz switching frequency
Limitation of output currents at output frequencies < 4 Hz
1
100 A
150 A