LBA 12 AVB (Heavy duty Steel arm - anti-ramming vehicle)0 pages
INDUSTRIAL
REINforced protection
Hea
vy duty Steel arm
“ nti-ramming vehicle”
a
>>
From 3 to 5 m – In IPE of 180 x 90
• Variable speed, programmable from 7 to 15 sec.
• Three-phase motor, power supply 230 V
• Adjustable rate of acceleration and braking
• Arm + high resistant support reinforced by support posts of 300 kg
Specificationst
Technical feature
Housing and doort
Steel sheet 4 mm protected by galvanization with blue RAL 5015 paint, door equipped with lock « Ronis 405 ».
Top cover: t
Steel sheet 3 mm protected by galvanization, with blue RAL 5015 paint.
Paint:t
Polyester powder baked at 250°, housing and cover RAL 5015.
Arm: t
Steel arm in IPE of 180 x 90 mm.
Half shell: t
Reinforced steel of 10 mm strenghtened for IPE of 180 x 90 mm.
Counterbalance:t
Compression spring ≤ 3800kg + bar, chain and sprocket (replaces the counterweight).
Emergency operation: t anual operation by 11 turns of the handle and an anti-restarting lock.
M
Geared motor: t
T
hree-phase 0,55 kw driven by a frequency converter with acceleration and braking ramps and variable
speed – power supply mono 230 V and output three-phase motor 230 V.
Double wheel converter and worm screw, lubricated for life.
Arm
Section
Drive
Voltage
Speed
m
mm
KW
A/230V
trs/mm
Variator
proportion
50 Hz
Operation time
mini/maxi
from 3,00 to 4,00
180x90
0,55
2,9
1410
900/1
10,0/10,0
7,0/12,0
from 4,00 to 5,00
180x90
0,55
2,9
1410
1280/1
14,0/14,0
8,0/15,0
Standard equipment: t arrier housing equipped with geared motor and half shell.
B
Isolating switch, frequency converter, multi-program control unit PL 2024.
Anti-condensation thermostatic heating 230 V 32 W.
Galvanized and plastified steel arm type IP 180 x 90 mm + reflecting bands class II.
Crank for manual emergency operations (with limited switches).
A set of keys for the maintenance hatch and a key to adjust the limited switches.
Installation, connection, implementation and maintenance manuals.
Two supports 200 x 200 with support leg sealed on the ground
Optional equipment: t
Safety magnetic loop - infrared cell – adapted logics – signalling systems etc.
LBA 12A
VB