Fiberoptic Acceleration Sensor0 pages
«0» MC
m
MC-monitoring SA
FAS M2 Datasheet
Fiberoptic Acceleration
Sensor
FAS-110 M2
FEATURES
• Immunity to magnetic and electrical fields
• Excellent electrical insulation between sensor head - feed-
through
• Dual output: acceleration and displacement
• Acceleration output sensitivity: 10OmV/g
• Displacement output sensitivity: 10 mV/um
• Available standard cable length: 10m
• Dual axis available with special assembly of two sensors
Monitoring solution
IZZIHI Endwinding monitoring
Typical applications
Hydrogenerators
Gearless millsdrives
Turbogenerators
DESCRIPTION
The FAS Fiberoptic Acceleration Sensor is designed to be non conductive and immune to electro-
magnetic interferences. Its optical link ensures an excellent electrical insulation between the sensor
and the instrumentation.
Its passive technology makes it ideal for shock and vibration measurements in areas where conven-
tional piezo-electric and piezoresisitive accelerometers may create hazards to machine and person-
nel and impair reliable operation.
The optical sensor body does not contain any metallic parts. The optical fibers are embedded and
protected by an integral 5mm thick PTFE tube. The standard available optical cable lengths is 10m.
The sealed feedthrough connector houses the optoelectronic and conditioning circuitry.
The sensor provides dual output, acceleration and displacement, simultaneously.
© MC-monitoring SA / 02.1xx.003_M2 / rev 3 / English
Page 1
"