21A Proportional series0 pages
Proportional solenoid valve
2/2 way N.C. - Direct acting
21A2KCV15-10
:PRESENTATION:
Solenoid valve designed for a fluid output proportional to
voltage change.
Minimum operational pressure is not required.
Mounting in any position.
Material used and tests carried out ensure reliability and long
life time.
TECHNICAL FEATURES:
Max. allowable pressure (PS)
40 bar
Ambient temperature:
See coils catalogue page for its compatibility.
Proportional response features:
Hysteresis
< 5%
Repeatability < 3%
Sensitivity
< 2%
Tensions range:
0-24 VDC
24 VDC impulse range modulation (600 ÷ 800 Hz),
(see general information:proportional S.V. operation).
These solenoid valves are not suitable for stagnating fluids, or
for fluids that being subject to evaporation may deposit solid,
calcareous or similar residues.
G 1/4
PIPES:
COILS:
8W - Ø 13
BDA - BSA
BDV
12W - Ø 13
UDA
155°C (class F)
180°C (class H)
155°C (class F)
COIL HOUSING AND COIL FORMER MATERIAL ARE MADE BY 100% VIRGIN MATERIAL.
Gaskets
V=FKM
(fluoroelastomer)
Temperature
- 10°C +140°C
Pipe
ISO 228/1
Code
G 1/4
21A2KCV15-10
Ø
Max viscosity
cSt
21
mm
°E
~3
1,5
Kv
Power
l/mn
watt
8
1,4
12
min
bar
0
Pressure
M.O.P.D.
AC bar DC bar
-
10
SOLENOID VALVE CALIBRATED AT 10 bar - Flow rate in air
Flow rate
COIL 12W
Flow rate
COIL 8W
Medium
Water, inert gas,
mineral oils (3°E), gasoline
P= 10 bar
Note Also available with brass body without lead.
P= 5 bar
P= 1 bar
The “ODE ” reserves the right to carry out technical and aesthetic modifications without prior notification.
28-02-2014
ODE
21A2KCV15-10
"