D 150 VW (E-Series SCVP) - EPC Wiring & Setup0 pages
Telephone:
Fax:
Website:
(414) 327-1700
(414) 327-0532
www.oilgear.com
The Oilgear Company
2300 S. 51st. Street
Milwaukee, WI USA 53219
LVDT
LOC.
Issued:
RHSFS
LHSFS
RHSFS
CW
CCW
CCW
ANALOG
INPUT 4
POLARITY
(LVDT)
845
NORMAL
NORMAL
NORMAL
NORMAL
ANALOG
INPUT 1
POLARITY
COMMAND
852
NORMAL
INVERT
INVERT
NORMAL
A
A
A
A
PORT
of
DELIV
DITHER
OUTPUT
CURRENT
NORMAL
NORMAL
NORMAL
100
NORMAL
100
17*
COR
840
7*
FINE
841
ANALOG
INPUT 4
(LVDT FB)
(GAIN)
512*
843
ANALOG
INPUT 4
(LVDT FB)
(OFFSET)
20*
Kp
804
0*
Ki
805
STROKE
CONTROL
GAIN
OPTIONAL ENTRY FOR CUSTOMER SPECIFIC APPLICATION
250
mA
803
802
%
875
MODULE
CURRENT
LIMIT
MODULE
POLARITY
CURRENT
CALIBRATIONS (SOFTWARE VALUES)
ELECTRONIC
* INITIAL CALIBRATIONS ARE ADEQUATE FOR MOST APPLICATIONS BUT MAY NEED TO BE OPTIMIZED FOR SPECIFIC APPLICATIONS
LHSFS
CW
PROGRAM MENU ITEMS
PUMP
ROT.
CONFIGURATIONS (SOFTWARE SWITCHES)
TECHNICAL DOCUMENT
81
D 150 VW (E-Series SCVP)
STROKE CONTROL WIRING
Aug, 2004
Bulletin 836269C
"