PT-3LF0 pages
PT-3LF
nnnnPortable Non-contact
nnnnThermometer
nnnnSpecifications
nnnn-Meaeu^Range- | -20 to 400" C (Display -30 to 430* C) |
Field of View | D 30/1000mm |
Sensing eleme^Wevelength | |
Response time | 1.5secJ90% |
Accuracy (EM3.95, at 25" C ±3" C) | ±1 % of reading value or ±2" C ±1 digit, whichever is grater |
Repeatability | ±1"C of reading value |
Display resolution | 1*C/*F |
Sighting method | Coaxial laser marker (Class 2) |
Emlsslvtty ratio (£) Adjustment | DARK (£=0.95)/BRiaHT (e=0.70) Swltehable |
Back-light function | Auto ON/OFF |
Temperature unit | 'C/'FSwitehable |
Measuring mode | NORMAL/MAX Swttchable |
Power supply | AA (Alkaline battery) x 2pcs. |
Battery life (with alkaline battery) | Approx. 100 hours with back-light and laser marker OFF |
Ambient temperature | Oto50*C |
Ambient humidity | 35 to 85%RH (Without dew condensation) |
Storage temperature | -20 to 60" C |
Dimensions | 162(H) x52(W)x 32(D) mm |
Weight (Incl. batteries) | 200g |
Standard Accessory: "AA* (Alkaline Battery) x 2pes
nnnnOptional Accessory: Black tape, Protective pouch
nnnn* Design and specifications may change for product improveme
nnnnt without prior notice.
nnnnField of View
nnnnK 500
nnnnLaser & Optical Axis
nnnnM The optical resolution values stated In "Field of View" are at 90% energy.
nnnn* The size of the target object should be sufficiently larger than the Field of View (spot size)
nnnnshown in the above illustration.
nnnnProtective Pouch for PT-3LF
nnnnwith lear window & belt clip.
nnnnAble to operate
nnnnJust open the
nnnnbutton.
nnnnwithout taking out of pouch.
nnnntop flip and push MEASURE Easy to carry with
nnnndetachable belt clip.
nnnnDisplay and Functions
nnnnField of view Chart
nnnnSafe Usage
nnnnA WARNING | Do not look Into the laser beam, nor point It directly at eyes. Even the reflection is harmful. This laser may cause eye injury or damage to your health. |
A CAUTION | This product is not a clinical thermometer; therefore, cannot be used for medical purposes. |
Environmental Warnings
nnnnWET. DO NOT USE IN WATER.
nnnnO KEEP THE THERMOMETER AWAY FHOM STRONG ELECTROMAGNETIC SOURCES OR LARGE
nnnnELECTROMAGNETIC FIELDS.
nnnnUsage In such environments may cause Irreparable damage or incorrect measurement
nnnnO KEEP THE THERMOMETER AWAY FROM DIRECT SUNLIGHT, DUST, HIGH TEMPERATURES
nnnnAND HIGH HUMIDITY DURING USE AND STORAGE.
nnnnThis may cause Irreparable damage or Incorrect measurement
nnnnO DO NOT EXPOSE THE THEMOMETER TO SUDDEN TEMPERATURE CHANGES.
nnnnSudden temperature change of the environment may causa Incorrect measu
nnnnthe thermometer reaches steady temperature before takrig measurement.
nnnnUsage Warnings
nnnnOAVOID MEASURING SHINY OBJECTS.
nnnnShiny objects, of which amlsalvlty value Is low, reflect surrounding temperatures. As this thermometer's
nnnnsensitivity to emissivity ie fixed at 0.95/0.70, the displayed temperature could differ from the actual temperature
nnnnof the object, which has the Different emissivity value. When you wish to measure shiny objects ike metals,
nnnnput a piece of optional black tape or apply black paint/maker on the surface and measure the masked area
nnnnusing emissivity setting of 0135.
nnnnO DO NOT LET THE THERMOMETER TOUCH THE OBJECT THAT IS BEING MEASURED.
nnnnThis Is a non-contact thermometer. Touching or getting too close to the objects with high temperatures may
nnnncause Irreparable damage or Incorrect measurement
nnnnProducts mentioned In this catalogue are equipped with Class 2 laser. In case of
nnnnre-export to foreign countries, please confirm the relevant regulation for laser products
nnnnin the destination country.
nnnn(^(^ ^ 3009-1 ^1-^4 2001.09.18*
nnnn"Take Care of the Environment"
nnnnThis catalogue uses recycled paper
nnnnOPTEX CO., LTD.
nnnn4-7-5 Nionohama Otsu 520-0601 JAPAN
nnnnTEL +81-77-524-6049 FAX +81 -77-524-1491
nnnnURL: www.optex.co.jp
nnnnNo. 74065-01 -0909-0109
"