NGA Centrifugal pumps with open impeller0 pages
NGA
Centrifugal pumps with open impeller
PERFORMANCE RANGE
INSTALLATION AND USE
•
•
Suitable for use with liquids that are not chemically aggressive towards the materials from which the pump is made.
The open impeller design allows liquids containing relatively
high levels of impurities to be pumped without the risk of the impeller clogging. As a result of these characteristics the NGA series
pumps are used specifically in industry and for transferring water
from canals, rivers, reservoirs, tanks, etc.
The pump should be installed in an enclosed environment, or at
least sheltered from inclement weather.
Flow rate up to 350 l/min (21 m³/h)
Head up to 20 m
APPLICATION LIMITS
•
•
•
•
•
•
Manometric suction lift up to 7 m
Liquid temperature between -10 °C and +90 °C
(up to +40 for the version with the technopolymer impeller)
Ambient temperature between -10 °C and +40 °C
Max. working pressure 6 bar
Passage of suspended solids up to Ø 10 mm
Continuous service S1
OPTIONALS AVAILABLE ON REQUEST
CONSTRUCTION AND SAFETY STANDARDS
•
•
•
EN 60034-1
IEC 60034-1
CEI 2-3
GUARANTEE
Pump with technopolymer impeller
Special mechanical seal
Other voltages or 60 Hz frequency
2 years subject to terms and conditions
CERTIFICATIONS
66