I-PROBE WIRELESS0 pages
API PRODUCT SPECIFICATIONS
I-PROBE
WIRELESS
Parameterttt
Remote Hand-Held Probing
Specification
Wireless Communication Distance
>40 m
Wireless Frequencytt
2.4 GHz
Lithium Ion Batterytt
3,6, or 9 working hrstt
Vertical Probe Position (Top)
100mm Effective Stand-off (w/ 50mm Stylus)
7m
15m
Above 15m
3D Points (3D U )
75μm
115μm
40μm + 5μm/m
Spatial Length (SLU )
45μm
85μm
10μm + 5μm/m
Sphere Radius (RU )
24μm
38μm
10μm + 2μm/m
Horizontal Probe Position
130mm Effective Stand-off (w/ 50mm Stylus)
7m
15m
Above 15m
3D Points (3D U )
100μm
140μm
65μm + 5μm/m
Spatial Length (SLU )
50μm
90μm
15μm + 5μm/m
Sphere Radius (RU )
30μm
45μm
15μm + 2μm/m
Vertical Probe Position (Bottom)
310mm Effective Stand-off (w/ 50mm Stylus)
7m
15m
Above 15m
3D Points (3D )
125μm
165μm
90μm + 5μm/m
Spatial Length (SLU )
65μm
105μm
30μm + 5μm/m
Sphere Radius (R )
34μm
50μm
20μm + 2μm/m
U
U
Definitions
3D Points Uncertainty (3DU)
3DU is the deviation between a point measured with the
Intelliprobe 360™ Wireless and the nominal position of that point.
Spatial Length Uncertainty (SLU)
SLU is the deviation between a length measured with the
Intelliprobe 360™ Wireless and its nominal value.
Sphere Radius Uncertainty (RU)
RU is the deviation between a measured sphere‘s radius and its
nominal value where the reference sphere has a radius between
10 mm and 50 mm.
Measurement Unit Specification
3DU, SLU, and RU are further specified as a function of the
distance between the laser tracker and the measured surface.
Technical specifications and descriptions may be subject to change.
©2013 Automated Precision Inc. All trademarks are property of their respective owners.