DATASURE0 pages
DataSure
DataSure Is Backed By Expert Starrett Support
Go Accurate. Go Fast. Go Wireless.
Time and motion tests comparing wireless data collection to handwritten and keyboard data
Starrett and its distribution partners are always available to help you make the most
evaluation of your specific needs and a ROI analysis to demonstrate payback. It’s
followed by expert installation advice and assistance to make sure you get your
failures, but it significantly saves time and money. A wireless system also eliminates wire-
system up and running immediately. If required, training and after-sales support
A
services help users easily transition to the new solution.
A Sample Application
System Specifications
Manual Data Recording:
Pen and Paper
Manual Data Recording:
Keyboard Results To PC
Wireless Data Collection
With DataSure
62 entry errors
4 entry errors
0 entry errors
22 time/motion elements
@ 19.7 seconds per part
20 time/motion elements
@ 15.3 seconds per part
17 time/motion elements
@ 6.6 seconds per part
Total: 37 time/motion elements for
a total of 28.9 seconds per part
Factors Affecting Accuracy
and Throughput:
nt
Illegible handwritten numbers
nt
Recording data is often shorthand
nt
range extender
transmits around
interference
end user feedback
on-tool data storage
wall mount or mobile
adapts to many tools
unique system ID
compact design
Factors Affecting Accuracy
and Throughput:
Factors Affecting Accuracy
and Throughput:
nt
Measurement must be suspended
in order to record measurement
nt
nt
Missed or incorrect keystrokes
Measurement technique is
maintained while capturing
the measurement
nt
Incorrect cell entry on
spreadsheet/form
nt
No interpretation or memory errors
nt
nt
When measuring, the value can
change when the inspector
releases the caliper
CR2450 lithium
Range
100 ft (30 m)
100 ft (30 m)
65 ft (20 m)
7.0 x 5.5 x 2.5 inches
(178 x 140 x 63.5 mm)
7.0 x 5.5 x 2.5 inches
(178 x 140 x 63.5 mm)
2.18 x 1.7 x 0.7 inches
(55.3 x 43.2 x 17.8 mm)
High efficiency with some
repetition effects
nt
AC power and
NiMH battery backup
Requires ordered repository
for data – spreadsheet, etc.
nt
USB
The caliper is not seated correctly
when released to key-in
a measurement
The inspector’s handwriting
was sometimes misread by the
transcriber (usually someone
other than the inspector)
dependent on environment
Dimensions
Additional errors occurred
with transcription at the PC
nt
USB connection
sends data to application
or database
The value can change when the
inspector releases the caliper
nt
End Node
Mistakes noted but not corrected
nt
Features
Router
Power
Measurement must stop in
order to be recorded
nt
Gateway
multi-file export features
Transcription (data entry):
15 time/motion elements
@ 9.2 seconds per part
Athol, MA 01331
(978) 249-3551
www.starrett.com
* his test compares DataSure with two common non-wireless procedures. It was designed to closely simulate actual production, involving 500 parts with three measurements each. With DataSure,
T
all three measurements and data recording were done in an average time of 6.6 seconds per part with no data errors. The results for the other methods are as illustrated above.
Test involved documenting each of the discrete time and motion elements and determining an elapsed time value. Three features on 500 parts were measured and recorded for each method.
Wireless Data Collection
of the DataSure Wireless Data Collection Solution for your shop. It starts with an
recording prove the benefits of DataSure.* Not only does DataSure capture data with zero
related placement, installation, safety, and cost issues.
®
Specifications subject to change. Bulletin No. 578. 10M/C. 06/09.
Co
mp
le
te
l
So
i
ut
on
To
Ensure
.
ty
ta
Da
t
In
egri
"