151XST Hazardous Location Warning Light0 pages
FEDERAL SIGNAL CORPORATION
Hazardous Location
Warning Light
Model 151XST
Federal Signal’s Model 151XST hazardous location strobe light
provides 80 high-intensity flashes per minute. This warning light is
available in 12-24VDC, 120VAC and 240VAC, 50/60Hz.
RUGGED DESIGN FOR USE IN
HAZARDOUS LOCATIONS
The Model 151XST strobe light is UL Listed and CSA Certified for
Class I, Division 2, Groups A, B, C and D; Class II, Division 1, Groups
E, F and G; and Class III.
The 151XST meets Type 4X water-tight, dust-tight, and corrosionresistant requirements and is constructed to IP66. This hazardous
location warning light has an aluminum base, coated for corrosionresistance, that can be ordered for mounting on a 3/4-inch NPT pipe
or a surface. The Dome Guard (included) fits over the glass dome to
protect it against accidental collision with moving equipment, such
as forklifts.
•t Available in 12-24VDC, 120VAC and
240VAC
•t Five dome colors
•t 10,000-hour high-intensity strobe
•t Available in 3/4-inch NPT pipe mountt
or surface mount
The 151XST produces 165 effective candela (ECP) and 520,000
peak candela. It is available in five dome colors including Amber,
Blue, Clear, Green and Red.
•t Dome guard included
•t Indoor/outdoor use
Federal Signal’s rugged 151XST strobe warning light is specifically
designed for hazardous locations or corrosive environments where a
very bright visual signal is required. This warning light can be used
for plant evacuation or other communication needs.
•t Type 4X, IP66 enclosure
•t Marine rated
•t UL and cUL t
Listed and CSA
Certified
Modelt
Voltaget
Operating t Flash Rate/t
Candela
Currentt MinutetPeak1tECP2t
Mount
1
2
151XST-_012-024-_t
12-24VDCt
1.3-0.60 ampst
80t
520,000t
165t /4" NPT Pipe
1
2
151XST-_120-_t
120VAC 50/60Hzt
0.35 ampst
80t
520,000t
165t 3/4" NPT Pipe
1
2
151XST-_240-_t
240VAC 50/60Hzt
0.18 ampst
80t
520,000t
165t 3/4" NPT Pipe
1Include
3
(S) Surface Mount
color: (A) Amber, (B) Blue, (C) Clear, (G) Green or (R) Red
2Indicates
Hazardous Location Rating:
T-Code at Maximum Ambient Temperature, °C
5
WA
y
yr
RRANT
Y
Hazardous Locationt
Class I, Div 2, Groups A, B, C & Dt
66°C
1
Peak candela is the maximum light intensity generated by
a flashing light during its light pulse
T2B/300º
2
ECP (Effective Candela) is the intensity that would appear
to an observer if the light were burning steadily
Class II, Div 1, Groups E, F & Gt
T5/100º
Class IIItt
T5/100º