LOADING
Diesel Generators / 20REODB/REOZDB0 pages
نسخه متنی
"
"
20REODB/REOZDB | |||||||||||||||||||||||||||||||
Model: | |||||||||||||||||||||||||||||||
KOHLER.POWER SYSTEMS | |||||||||||||||||||||||||||||||
Compact Diesel | |||||||||||||||||||||||||||||||
Q9001 | |||||||||||||||||||||||||||||||
Standard Features Kohler Co. provides one-source responsibility for the generating system and accessories. Օ The generator set and its components are prototype-tested, factory-built, and production-tested. The generator set is CSA certified, file #LR 955. Օ UL 2200 listing is available. The generator set engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 4 nonroad emissions regulations. Օ The generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. A one-year limited warranty covers all systems and components. Two- and five-year extended warranties are also available. Օ Four-point mounting with vibration isolators. Static-excited (REODB) or brushless (REOZDB) alternator. Օ Voltage regulation of ±1.5%. Sustained short-circuit capability. Օ Remote start 12-pin connector. Single-side access. Օ Enclosure features: o Weather and sound enclosures are available. o All weather and sound enclosures are rated for 150 mph winds. o Enclosures reduce sound levels and protect the generator set from the elements, animal intrusion, and unwanted entry. o Enclosures have a fade-, scratch-, and corrosion-resistant Kohler cream beige finish with lockable, flush- mounted door latches. o Acoustic insulation meets UL 94 HF1 flammability classification. | |||||||||||||||||||||||||||||||
EMS | |||||||||||||||||||||||||||||||
NATIONALLY REGISTEREC | |||||||||||||||||||||||||||||||
Generator Set Ratings | |||||||||||||||||||||||||||||||
130 °C Standby Hz Ph kW/kVA 20/20 | Rise Rating Amps 83.3 69.5 68.8 60.2 65.7 60.2 38.0 30.1 | 105 °C Rise Pr me Rat ng kW/kVA Amps 18/18 75.0 18.0/22.5 62.6 14.9/14.9 61.9 18.0/22.5 54.2 18.0/22.5 59.1 18.0/22.5 54.2 18.0/22.5 34.2 18.0/22.5 27.1 | |||||||||||||||||||||||||||||
Alternator Voltage 4H7_120/240 120/208 120/240 120/240 4J7 127/220 139/240 220/380 277/480 | |||||||||||||||||||||||||||||||
J | |||||||||||||||||||||||||||||||
20.0/25.0 16.5/16.5 20.0/25.0 20.0/25.0 20.0/25.0 20.0/25.0 20.0/25.0 | |||||||||||||||||||||||||||||||
60 3 60 60 60 60 60 60 | |||||||||||||||||||||||||||||||
RATINGS: All three-phase units are rated at 0.8 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. Prime Power Ratings: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. Obtain the technical information bulletin (TIB-101) on ratings guidelines for the complete ratings definitions. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler® generator set distributor for availability. GENERAL GUIDELINES FOR DERATING: ALTITUDE: Derate 0.8% per 100 m (328 ft.) elevation above 200 m (656 ft.). TEMPERATURE: Derate 6.0% per 10°C (18°F) temperature above 25°C (77°F). |