Safety Relay SR6 D/M0 pages
General Purpose
Force Guided Relays
SCHRACK
Force Guided Relay SR6 D/M
nt4
pole relay with force guided contacts according to EN 50205
insulation distances between electrical circuits
ntHigh
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays.
ZT
Approvalstt
Coil Data (continued)tt
Technical data of approved types on request.tt
Coil versions, DC-coil
t Coilt
Ratedt
Operatet
Releaset
Coilt
Rated coil
t
codetvoltagetvoltagetvoltaget
resistancet
power
tt
VDCtVDCtVDCt
Ω±10%1)tmW
t
024t24t18t 2.4t480t
1200
t036t
36t
27t
3.6t
1080t
1200
t040t
40t
30t
4.0t
1333t
1200
t048t
48t
36t
4.8t
1920t
1200
1)t1200
t060t
60t
45t
6t
3000
t110t
110t
83t
11t
100801)t1200
VDE 128935, UL E214024, TUV 968/EL 350, CQC06017015577
Contact Datatt
Contact arrangementt
3 form A + 1 form B contacts
ttt
3 NO + 1 NC,
ttt 2 form A + 2 form B contacts
ttt
2 NO + 2 NC
Rated voltagett
250VAC
Max. switching voltagett
400VAC
Rated currenttt
8A
Contact materialtt
AgSnO2
Contact stylett single contact, force guided
tt
type A according to EN 50205
Min. recommended contact loadtt
5V, 10mA
Initial contact resistancett
≤100mΩ at 1A, 24VDC
ttt
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without loadt
6/150min-1
Contact ratings, IEC60947-5-1,
t on 1 form A (NO) contacttt
AC15-5A
ttt
DC13-6A
Mechanical endurancett
10x106 operations
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Insulation Datatt
Coil datatt
Coil voltage rangett
5 to 110VDC
Coil versions, DC-coil
t Coilt
Ratedt
Operatet
Releaset
Coilt
Rated coil
t
codetvoltagetvoltagetvoltaget
resistancet
power
tt
VDCtVDCtVDCt
Ω±10%1)tmW
t
005t5t 3.8t0.5t21t
1190
t
006t6t 4.5t0.6t30t
1200
t
009t9t 6.8t0.9t68t
1191
t012t
12t
9t
1.2t
120t
1200
t
018t18t13.5t 1.8t270t
1200
t
021t21t16t 2.1t368t
1198
10-2012, Rev. 1012
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Initial dielectric strength
t between open contactstt
t between contact and coiltt
t between adjacent contactstt
t
in longitudinal directiontt
Clearance/creepage
t between open contactstt
t between contact and coiltt
t between adjacent contactstt
t
in longitudinal directiontt
Insulation to EN 50178, type of insulation
t between contact and coiltt
t between adjacent contactstt
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
1500Vrms
4000Vrms
3000Vrms
4000Vrms
microdisconnection
≥5.5/5.5mm
≥5.5/5.5mm
≥15/15mm
reinforced
reinforced
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
1
"