ATESA 203L0 pages
TEDDINGTON APPLIANCE CONTROLS LTD
ATESA 203
GAS LOG TAP
? Approved
CE, CSA
? (40”) WG Max. Pressure
150mbar
?
150°C Max. Working Temperature (300°F)
?
Multi-pose Positioning
?
Low Profile Construction
?
90,000Btu/hr Flow Rate (1” pd with Natural
gas)
?
Adjustable Pilot Rate
Application
The Gas Log Tap has been designed for the
North American Gas Log market. It was the
first slim line high temperature rated 300°F
purpose control for this market. These two
features alone makes it the ideal control to fit
directly to the tray burner and make the control
non-intrusive for the end user.
Physical Description
The ATESA 203-L log tap body is constructed
of brass, connections are illustrated overleaf.
the safety system used in this control is a well
proven thermoelectric system that gives a
positive and fast shutdown if the pilot flame is
lost. It can also be used in conjunction with
ODS pilots. Because of the high throughputs
that can achieved this control can be ideally
ATESA 203-L
suited for many catering applications that require
a safety control to be fitted in a harsh
environment.
Operation
This consists of pushing the spindle in to clear
the niting followed by rotation to the ignition
position. The spindle is then pushed in to allow
gas to the pilot, dependant on type. The
temperature settings are obtained by further
rotation of the spindle.