AX0 4-20 mA transmitter MN AX0 lube0 pages
MAX FLOW SIZES FROM
10 TO 70 GPM
(60 TO 265 LPM)
MAX LIQUID PRESSURE 300 PSI (20.69 BAR)
Flow rate indicator with switch(es) or transmitter.
MN LUBE
MN Series, "A" style control box
Flow meters,
Flow switches and
Flow transmitters
For Circulating
Lubrication Oil
DESCRIPTION
These are variable area meters with a
spring biased semi-circular vane that
opens wider with more ow. They are
installed in-line in any position. Straight
pipe runs before or after the meter are
not required. The simple mechanical
connection directly drives pointers,
switches and transmitters.
CALIBRATION
All ow meters are individually
calibrated for uids with the
viscosity you specify (up to 3000
SSU/660 Centistokes). We also
compensate for your uid’s specic
gravity. For NIST Traceability
please consult factory.
ENGINEERING DATA
Maximum uid temperature:
200°F (95°C)
C
D
Maximum ambient temperature:
150°F (65°C)
F
A
G
B
Readout accuracy, full scale: ±2%
Switch repeatability 1% of actual
ow.
E
Fluid enters at A, passes around the
semi-circular vane B, exits at outlet
C. The vane resists the ow because
of the spring D. The further the vane
is pushed the larger the passageway E becomes. This minimizes the
pressure drop. The vane shaft turns
to operate the pointer F and remote
signal devices such as the switch G.
FLOW & PRESSURE DROP
Units impose a pressure drop that increases with ow from 1.9 to 3.8 PSI.
STANDARD OFFERING: Control Box “A”
CONSTRUCTION MATERIALS
5.50 [140mm]
PORT TO PORT
2.41
[61mm]
6.84 STD. SPRING
[174mm]
The body is aluminum with nylon.
Internal moving parts are stainless
steel. Seals are Buna-N.
3/4" NPT
CONDUIT
CONNECTION
A
B
LINE CONNECTION
Ports are threaded and can be NPT
(1/2 to 2") or SAE straight thread (1/2
to 1-1/2"). Metric threads such as
BSPP or BSPT are also available.
C
3.31
[84mm]
MAX PORT SIZE (NPT)
1/2 TO 1-1/2
2
A
5.96
5.96
1
AA
8.60
9.58
B
4.54
4.91
C
5.96
6.12
6.00
[152mm]