MS Modulating control sytems propanegas0 pages
MS Modulating control units/propane gas
MODULATING CONTROL UNITS MS 20, MS 40 AND MS 60
With the MS 60, a drying plant operating to a maximum of 60 kg of propane gas per hour, 40 kg for the MS 40 and 20 kg
for the MS 20 can be controlled in which several heaters (also all horizontal models) can be connected.
The modulating control unit ensures that the heat capacity is automatically and constantly adapted to the requirement at
any moment. This is a continuous process. The drying of products at highly fluctuating outside temperatures can thus be
improved considerably. The desired temperature is set on the control panel which measures the temperature of the crop
by means of a sensor. The panel controls the gas pressure regulator with a servo motor which provides more or less gas
flow to the burners and the temperature is adjusted until the preset value is reached. The measured temperature value is
digitally readable.
The servo motor and the gas pressure regulator of these units are also available separately and can be connected to a
central storage computer.
MS 60 stand alone modulerend regelsysteem
The smaller unit MS 20 is supplied as a separate controller, gas pressure regulator and servo motor. On this unit 2 to 6
heaters can be connected.
MS 24 Modulating gas valve with servo
motor, (DVGW approved for Germany)
ADVANTAGES
MS 20: t
•ttttttt Modulating drying of smaller amounts of crop for an economic price.
MS 40 and MS 60: • Accurate adjustable crop temperature (to 0,1°C).
• Saving on cost of fuel
•tttten Superior product quality .
• Modulate different sections at the same time.
MODULATING CONTROL UNITS
estelnummer
Modulating control unit MS 20 (1-20 kg propane), adjusting range 0,4-2,0 bar, Ø connection 1/4” IN-3/8” OUT, supply 230 V
40.301.018
Modulating control unit MS 40 (1-40 kg propane), adjusting range 0,4-2,0 bar, Ø connection 1/4” IN-3/8” OUT, supply 230 V
40.301.069
Modulating control unit MS 60 (1-60 kg propane), adjusting range 0,4-2,0 bar, Ø connection 1/4” IN-3/8” OUT, supply 230 V, 3-point control with manual operation
40.301.019
Connection accessory for external computer (instead of complete MS):
Modulating gas valve with servo motor MG 60, Ø connection 1/2”:
Modulating gas valve with servo motor MG 60, supply 230 VAC 50/60 Hz, 3-point control with manual operation
40.301.029
Modulating gas valve with servo motor MG 60, supply 230 VAC 50/60 Hz, 3-point control , pot.meter 5K-Ohm for feedback
40.301.055
Modulating gas valve with servo motor MG 60, supply 24 VAC 50/60 Hz, control 0-10, Vdc analog
40.301.056
Modulating gas valve with servo motor MG 60, supply 24 VAC 50/60 Hz, 3-point control, pot.meter 1K-Ohm for feedback
40.301.052
Modulating gas valve with servo motor MG 60, supply 24 VAC 50/60 Hz, 3-point control
40.301.054
MG 20 - MG 40 Modulating gas valve
with servo motor
Modulating gas valve with servo motor MG 40, adjusting range 0,4-2,0 bar, Ø connection 1/2”:
Modulating gas valve with servo motor MG 40, supply 230 VAC 50/60 Hz, 3-point control
Modulating gas valve with servo motor MG 40, supply 24 VAC 50/60 Hz, 3-point control for feedback
MG 60 Modulating gas valve
with servo motor
40.301.066
40.301.067
Modulating gas valve with servo motor MG 20, adjusting range 0,4-2,0 bar, Ø connection 1/4” IN-3/8” OUT:
Modulating gas valve with servo motor MG 20, supply 230 VAC 50/60 Hz, 3-point control
40.301.058
Modulating gas valve with servo motor MG 20, supply 24 VAC 50/60 Hz, control 0-10, Vdc analog
40.301.064
Modulating gas valve with servo motor MG 20, supply 24 VAC 50/60 Hz, control 0-10, 3-point control
40.301.065
Modulating gas valve with servo motor MG 20, supply 24 VAC 50/60 Hz, 3-point control with pot.meter
40.301.075
Modulating gas valve with servo motor MS24, (DVGW approved for Germany) supply 230 Vac 50/60 Hz, 3-point control
40.301.077
Special equipment
Temperature probe PT 100 with 10 m cable
40.301.033
Temperature probe PTC 100 with 10 m cable
40.301.063
Fire protection system for crop drying (propane gas), supply 230 V
40.301.045
- Magnetic gas valve for propane gas, 230 V, to place in gas supply pipe (max. 60 kg/hr)
40.301.047
- Magnetic gas valve for propane gas, 24 V, to place in gas supply pipe (max. 60 kg/hr)
40.301.080
- Room/Maximum thermostat 0/60ºC
40.301.049
Suspension bracket GA 42 E
40.277.033
Suspension bracket GA 60/85/110 E
40.301.007
Shell coupling (male 1/2”)
40.252.259
Gas quick coupling (female 3/8”)
40.301.025
Gas quick coupling (female 1/2”)
40.301.032
Fire protection system for crop drying
Modulating gas valve with servo motor
(propane gas)
"