Falcon F35 & F450 pages
Falcon F35 & F45 Digital Panel Meters
• 1/8 DIN Indicator
• 3-1/2 or 4-1/2 digit bright red LED display
• Front panel pops off for easy decimal
point setting and display scaling
• Only 3.12" (79mm) required behind panel
• Optional excitation output
• NEMA 4X enclosure optional, using part # 45003
Mounting Requirements_
The Falcon series 1/8 DIN indicators require a panel cutout of
1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon
into a panel cutout, remove the clips from the side of the meter.
Slide the meter through your panel cutout, then slide the mount-
ing clips back on the meter. Press evenly to ensure a proper fit.
Tighten screws.
Specifications
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ISOLATION
ACCURACY @25°C
F45 DC Process/Voltage
F35 DC Process/Voltage
F45 DC Current
F35 DC Current
F45 AC Voltage/Current
F35 AC Voltage/Current
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Warm-up Time
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
Temperature Coefficient
F35 AC/TRMS (Voltage/Current)
F35 DC (Voltage/Current/Process)
F45 AC (Voltage/Current)
F45 DC Current
F45 DC (Voltage/Process)
Dimensions
7-segment, red LED
0.56" (14.2mm)
user-programmable,
internally or on the terminal block
most significant digit = "1"; other digits
blank
Automatic, with "-" indication,
"+" indication implied
120 or 220VAC, ±10% 50/60Hz
9-32DCV, ±1%
F35: 3VA, F45: 2VA
250V RMS MAX
±0.02% of reading ± 1 count
±0.1% of reading ± 1 count
±0.05% of reading ±1 count
2A ± 5 counts 5A ± 5 counts
+0.1% of reading ± 1 count
2A ± 5 counts, 5A ± 5 counts
±0.5% of reading ± 35 counts
±1 % of reading ± 5 counts (45Hz-1 KHz)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
Less than 15 minutes
F35=50dB, 50/60Hz; F45=60dB, 50/60Hz
(w/1 KQ unbalanced @ 60Hz) 90dB min.
Dual slope integration
F35=3 samples per second, nominal;
F45=2.5 samples per second, nominal
3.78"x1.89"x.51"
2.94"
3.62" X 1.77"
94V-1, UL rated Noryl®
9.0oz (255.1 g)
(±0.1%±0.5count)/°C
(±0.01% ±0.05 count)/°C
(±0.05% ± 0.5 count)/°C
(±0.01% ±0.1 count)/°C
(±0.05% ±0.1 count)/°C
4.04"
3.59"
1