Topcable_eng_07_topweld_H01N2D0 pages
HD 22.6 / UNE 21027-6
Based on:
LOW VOLTAGE 100/100V
TOPWELD H01N2-D
TOPWELD
H01N2-D
DIMENSIONS
Cross Section
(mm2)
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
The special cable for welding.
DESIGN
Conductor
Electrolytic copper, class D (flexible), based on UNE 21027-6
Outer sheath
Thermosetting rubber (type EM5). Black colour.
Diameter
(mm)
8,0
9,1
10,3
11,4
13,4
15,5
17,4
19,4
21,5
23,9
Weight
(Kg/km)
139
195
279
373
520
724
947
1.197
1.477
1.788
100%
100
135
180
225
285
355
430
500
580
665
Maximum current for a 5 minute period
85%
60%
103
145
195
245
305
380
470
540
630
720
108
175
230
290
365
460
560
650
750
860
35%
122
230
300
375
480
600
730
850
980
1.120
Voltage drop (V)
(100A, 10 m)
2,450
1,560
0,998
0,709
0,493
0,348
0,264
0,206
0,166
0,136
APPLICATIONS
The Topweld H01N2-D cable has been specially designed for transmitting high currents
between the welding generator and the electrode. The high degree of flexibility makes
using the welding tool easier and also keep knots from forming in the cable that could
cause the internal conductor to break. It can also be used in automatic welding machines,
transport belts, and production or assembly lines, for example in automobile assembly
lines.
CHARACTERISTICS
INSTALLATION CONDITIONS
Flexible
conductor
class 5
Outdoor installation: permanent
Minimum service
tempersture:
-20ºC
Meter by meter
marking
Water resistance
AD3 aspersion
Maximum service
temperature 85ºC
Flame
non-propagation
Chemical &
Oil resistance:
permanent
For further technical data
please request this cable’s
technical datasheet.
Maximum
short-circuit
temperature:
250ºC (max. 5 s)
33
Minimum bending
radius 5x cable
diameter
Impact resistance
AG2 medium
impact
Grease & mineral
oils resistance:
excellent
Top Cable reserves the right
to carry out any modification
whatsoever without giving
previous notice.
National norm / European: EN 60332-1 International norm: IEC 60332-1
Abrasion
resistance:
excellent
Industrial use
Welding
34