Double vane pumps0 pages
www.atos.com
Table A180-6/E
Double vane pumps type PFED
fixed displacement
ᕈ
ᕇ
OUT
PFED are fixed displacement double
vane pumps ባቤ composed by two cartridges of pumps type PFE (see tab.
A005) assembled in a main body having
one inlet port ቦ and two outlet ports ቧቨ.
ᕉ
OUT
IN
PFED-43 are composed by one cartridge
of PFE-41 and one cartridge of PFE-31.
PFED-54 are composed by one cartridge
of PFE-51 and one cartridge of PFE-41.
Suitable for hydraulic oils according to
DIN 51524...535 or synthetic fluids having
similar lubricating characteristics.
These pumps can be assembled, as
second element, with PFE-4 and PFE-5 to
obtain triple pumps, see tab A190.
ᕆ
ቢ
ባ
ቤ
ብ
ቦ
ቧ
ቨ
1
ᕃ
ᕄ
Mounting according to SAE J744.
Easy installation as inlet and outlet ports
can be assembled in any of four relative
positions.
Easy maintenance as pumping cartridge
can be replaced in a few minutes.
Hydraulic symbol
ᕅ
body
first cartridge: stator, rotor, vanes, balanced plates
second cartridge: as above
shaft
inlet port
first outlet port
PFED-43
second outlet port
Wide variety of displacements: from
29+16 up to 150+85 cm3/rev.
Max pressure up to 210 bar.
MODEL CODE
PFED
-
43
045
/
022
/
1
D
TA
**
/*
Seals material:
omit for NBR (mineral oil & water
glycol)
PE = FPM
Fixed displacement
double vane pump
Series number
Size of cartridges:
43 = composed by:
one cartridge of PFE-41 + one
cartridge of PFE-31
Ports orientation, see section ݚ
Direction of rotation (as viewed at the shaft end):
D = clockwise (supplied standard if not otherwise specified)
S = counterclockwise
54 = composed by:
one cartridge of PFE-51 + one
cartridge of PFE-41
Note: PFED are not reversible
Drive shaft, see section ݜand :ݝ
Displacement of first element [cm3/rev], see section ݙ
cylindrical, keyed
1 = supplied standard if not otherwise specified
2 = according to ISO/DIN 3019
3 = for high torque applications
Displacement of second element [cm3/rev], see section ݙ
splined
5 = for PFED-43: according to SAE B 13T 16/32 DP (13 teeth)
for PFED-54: according to SAE C 14T 12/24 DP (14 teeth)
6 = (only for PFED-43) = according to SAE C 14T 12/24 DP (14 teeth)
7 = (only for PFED-43) = similar to shaft type 6. It is used when PFED-43 is the last
element of a multiple pump
2
MAIN CHARACTERISTICS OF DOUBLE VANE PUMPS TYPE PFED
Installation position
Any position.
Loads on the shaft
Axial and radial loads are not allowed on the shaft. The coupling should be sized to absorb the
peak horsepower developed.
Ambient temperature
from -20°C to +70°C
Fluid
Hydraulic oil as per DIN 51524...535; for other fluids see section ݗ
Recommended viscosity
max at cold start
max at full power
during operation
min at full power
Fluid contamination class
800 mm2/s
100 mm2/s
24 mm2/s
10 mm2/s
ISO 4401 class 21/19/16 NAS 1638 class 10 (filters at 25 µm value with ß25 ≥ 75 recommended)
Fluid temperature
-20°C +60°C
Recommended suction line pressure
from -0,5 to 1,5 bar for speed up to 1800 rpm; from 0 to +1,5 bar for speed over 1800 rpm
-20°C +50°C (water glycol)
-20°C +80°C (/PE seals)
A180
"