Ventilated Distribution Transformers | |||||||||||
K-Factor Transformers | |||||||||||
K-Factor transformers are designed to reduce the heating effects of harmonic currents created by loads like those shown in Chart A. The K-Factor rating is an index of the transformer's ability to withstand harmonic content while operating within the temperature limits of its insulating system. SolaHD K-Factor transformers have UL ratings of K-4, K-13, and K-20. The SolaHD K-Factor design is a specialized transformer that offers these benefits: • Conductors capable of carrying the harmonic currents of non-linear loads without exceeding the temperature rating of the insulation system. • A transformer design that takes into account the increase in naturally occurring "stray" losses caused by non-linear loads. These losses cause standard transformers to dramatically overheat and substantially shorten design life. • A core and coil design that manages the DC flux caused by triplen harmonics. As these harmonics increase, they cause additional current to circulate in the delta winding. This produces a DC flux in the core which leads to core saturation, voltage instability and overheating. Features • Conductors to carry harmonics of a K-rated load without exceeding insulation temperature ratings • UL 1561 listed up to K-20 rated protection • Rated temperature rise of 150°C, 220°C insulation • Shielded for quality power • Basic design takes "stray losses" into account and functions within safe operating temperatures • Core and coil design engineered to manage the zero sequence flux caused by triplen harmonics • Provides 100% rated current without overheating the windings or saturating the core | |||||||||||
Listed | |||||||||||
E25872 | |||||||||||
Accessories and Optional Design Styles* • Wall mounting brackets (500 lbs maximum) (Item WB1C) • Weather Shields (UL-3R) • Totally enclosed non-ventilated designs (TENV) (Non UL) • Low temperature rise units available • Open core and coil designs (UL Recognized) • Copper Wound designs • Alternate voltages • Compliant to NEMA TP-1 Standards * Not all optional designs are UL listed. Contact Technical Services. | |||||||||||
Chart A: Typical Load K-Factors | |||||||||||
Load K-Factor Electric discharge lighting..............................................................K-4 UPS with optional input filter..........................................................K-4 Welders.........................................................................................K-4 Induction heating equipment.........................................................K-4 PLCs and solid state controls........................................................K-4 Telecommunications equipment (e.g.. PBX).................................K-13 UPS without input filtering............................................................K-13 Multiwire receptacle circuits in general care areas of health care facilities and classrooms of schools, etc....................K-13 Multi-wire receptacle circuits supplying inspection or testing equipment on an assembly or production line...................K-13 Mainframe computer loads..........................................................K-20 Solid state motor drives (variable speed drives)............................K-20 REPRINTED WITH PERMISSION FROM EDI MAGAZINE | |||||||||||
Visit our website at www.solaheviduty.com or contact Technical Services at (800) 377-4384 with any questions. | |||||||||||
194 |