VLM ClimaCORR® Truhe0 pages
V B« PI Product Data Sheet
ClimaCORR® CC 1000-TL FR (-40°C...+80°C)
Humidity in the Constant
Humidity mode {CH)
Regulated Humidity mode
(without climate module)
Tested device: ClimaCORR® CC 1000-TL FR
Regulated Humidity mode
(with climate module)
10 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100
Temperature |°C]
Figure 1 Operating range (regulated
humidity vs temperature]
Applicable Corporate Cyclic Climate Tests
* VDA 233-102 "New"
* DIN EN ISO 11997-1:2006 Cycle B (previously VDA 621-415)
VW PV 1210 (external climate module required)
i- Nissan CCT1
4- Renault ECC1 (external climate module required)
Figure 2 Patented Controlled Water
Condensation (CWC) system
Order Information
Model: ClimaCORR® CC 1000-TL FR
Article number:
- V.785.272.570 (-30°C <T<+80°C)
- V.785.372.570 (-40°C <T<+80°C)
Sales & Support:
B +49 5205 87963 0
Monday to Friday
8:00 am - 17:00 pm
VLM LabortechnikGmbH
Heideblumchenweg 50
33689 Bielefeld
info@vlm-labtec.com
www.vlm-labtec.com
Specification subject to changes
Pictures might differ from original
Product Description
Compact chest model of the test chamber developed for the automated
conduction of advanced cyclic corrosion tests pursuant to the most of
the corporate standards of the international automotive industry i.e.
VDA 233-102 "NEW", DIN EN ISO 11997-1:2006 Cycle B (VDA 621-
415), VW PV 1210, Nissan CCT1 as well as the standard Salt Spray test
acc. to ISO 9227 and High Humidity 6270-2. Full overview of applicable
tests is shown on page 2.
Customer Benefits
Operating temperature range -40°C up to +80°C is a unique specification among the
corrosion test chambers currently available on the market
Advanced steel design of the chamber (with ECTFE coating) allows for short
temperature and humidity transient times making this test chamber perfectly
suitable for accelerated corrosion tests - this results in time and energy savings
during the operational lifetime
The patented VLM technology allows the best possible reproducibility of the climate
conditions being created in the test chamber regardless the environmental
conditions and geographical location - same type of VLM corrosion test chamber will
produce same test results in Germany, China or Egypt. In total 9 different sensors
are monitoring all relevant test parameters being temperature, humidity, air flow
during the drying phase and the purity of the demineralized water
The test chamber made of steel is more robust and less susceptible for damages
compared to the competitive products made of glass reinforced plastic
Lower cost of ownership compared to the competitive products where the test
chamber is made of glass reinforced plastic (shorter test periods, better energy
efficiency, easier for service and maintenance, longer life cycle, more resistive to
mechanical damages)
User friendly, menu guided and intuitive control system based on a touch screen in
which most common standard corrosion tests are already preconfigured
I CC 1000-TL FR | VLM GmbH
Version: V4/25.08.2014
"