SONOSPOT0 pages
DETECTION OF
LEAKAGES AND
PARTIAL DISCHARGES
NTLADUNGEN
General Description:
The parabolic probe SONOSPOT for the SONAPHONE detects sound
detec
cts
emissions in the ultrasonic frequency range caused by compressed-air
compr
ressed-air
leakages and electric partial discharges. It allows a reliable and precise
a
detection even over longer distances.
Ultraschallsensorik Halle GmbH
Nauendorfer Straße 2
D-06112 Halle (Saale)
Tel. +49 / (0)345 / 1 33 17-0
Fax +49 / (0)345 / 1 33 17-99
www.sonotec.de
e-mail: SONOTEC@sonotec.de
Characteristics:
High sensor sensitivity due to the parabolic reflector
Great operating distances up to 20 m (dependent on signal intensity)
Very precise directivity
Insensitive to background noises in the audible sound range
d
Reliable locating with a calibrated red dot sight, can be replaced
b
by a laser pointer set upon request
Robust and transparent reflector for optimal sight
Optimal ergonomics and operation
Easy to transport
Technical Data:
Reflector diameter: 270 mm
Frequency range: 40 kHz
Dimensions in mounted condition: L 390 mm, W 270 mm & H 440 mm
Lightweight: 700 g
Version: 2 | Status: 2011-11-29 | Subject to change without prior notice
t