MLR - Magnetic level indicator with colored rollers0 pages
magnetic level indicator model MLR
Column of colored rollers indicate the level in the tank
Badotherm magnetic level gauges are designed for gauging liquids where
glass, gaskets threaded connection etc cannot be tolerated because of
corrosion problems, toxic gases, dangerous fluids etc. Model MLR features a
column of magnetic rollers which are white on one side and red on the
other. The rollers are made from plastic with a distance of 10 mm between
the axes. As the float moves up or down the bunched field of the permanent
magnet mounted in its top section pulls the rollers through a rotation
of 180 degrees, thus changing color. As the float rises, the rollers are turned
from white to red and as the float falls, they are changed back to white
again. This model can be used with alarm switches and a transmitter with
4-20 mA output. The chamber on which the indicator is mounted must be
of a non magnetic material. The standard is AISI316 but can also be
supplied in PP, PVDF, PVC etc on request.
level instrumentation
For technical data sheets and dimensional drawings please refer to our website www.badotherm.com 303
01/01/2006 rev 2
Technical specification
Cage 2” NB pipe AISI316 / PP / PVC / PVDF
Maximum center to center 6000 mm ( side / side )
Depth 3000 mm ( top )
Connecting flanges ANSI B16.5 / DIN / JIS
Maximum viscosity 500 cst
Pressure rating PN16 … PN100
Maximum operating temperature 300 °C for AISI316
80 °C for PVDF
60 °C for PP
40 °C for PVC
Minimum SG of liquid 0.40
Roller inaccuracy 1%
Minimum difference in SG between interface liquid 0.10
Accessories and specials
Alarm switches
Transmitter 4-20 mA
Interface measurement
Heating jackets
Drain / vent / isolation valves
Float sink indication
Salient features
Un-pressurised float without mechanical or magnetic guide rails
360 degrees magnetic coupling
Fully corrosion resistant system
Not affected by pressure, vacuum, temperature foam and viscosity
Minimum sensitivity to density variation
Glandless construction
Permanent indication without external power supply
Fully adjustable limit switches
Eccentric drain can not be blocked by the float
Safe environmentally friendly and trouble free construction
* for special applications consult factory
5.1.1