GAS 222.200 pages
Sample gas probe GAS 222.20
TE©lMIIM©L©mm
Flow Diagram
I—s
Description:
Heated sample gas probe with downstream filter
and weather protection shield
Filter election can be replaced without tools
Effective insulation and protection shield
Electronic heater up to 200°C with low/high
temperature alarm and display
Dust concentration up to 2g/m3
Not for hazardous areas
Technical Data:
• Material: 1.4571
• Seals: Graphite/1.4404 and see filter element
• Operating temperature: max. 200°C
• Max. working pressure: 6 bar
• Voltage: 230 V, 2,0 A, 50/60Hz
or 115 V, 3,8 A, 50/60Hz,
• Temperature range: +50 to +200°C
• Alarm: adjustable ±5.....30K from set point,
factory set 15K
current max. 1A
• Protection class: IP54
• Ambient temperature: -20 up to +70°C(may be
limited by options)
Order information: Base units:
• GAS 222.20 230V p/n 4622220
• GAS 222.20 115V p/n 4622222 '
In combination with heated extensions (see
accessories) you have to add a "G" to p/n. For
example: 4622220G.
Options:
To customize the base unit to meet the needs of any
application, please refer to data sheet DE461099
"Accessories for Gas Sample Probes".
Various probe tubes
Heated/unheated extensions
Filters
Calibration gas port
ANSI flange 3"
For general information see data sheet "Gas Sample Probes GAS 222" DE461000.
DE 46 1020
12/2006
Buhler Technologies GmbH
D - 40880 Ratingen, Harkortstr. 29
Tel.: + 49 (0) 2102 / 4989-0 Fax: + 49 (0) 2102 / 4989-20
Internet: www.buehler-technologies.com
e-mail: analyse@buehler-technologies.com
"