Seal Supply Systems
Quench Fluid Systems
QFT2000
Features
Quench fluid supply systems are used to supply
single or tandem mechanical seals. They act as
a convenient fluid reservoir. The exchange of
fluid takes place by the thermosiphon principle
or by forced circulation, e.g. with a pumping
screw. The QFT2000 stainless steel tank is
equipped with sight-glasses for monitoring the
MIN/MAX level and can be fastened with a lug
fixture. The leakage overflow can be selectively
discharged.
Circulation in accordance with API 682 / ISO
21049: Plan 51, Plan 52
Advantages
Available in a range of different material
combinations: suitable for a wide range of
demanding operating conditions
Design for medium temperatures of up to
+200 °C (+392 °F)
Tank made of 1.4571: high resistance to
corrosive media
Integrated overflow for selective discharge of
leakage
Instead of the sight-glass it is possible to use
a level switch to monitor the fluid volume
Combined filling and ventilation filter in the
quench fluid tank for reliable operation
Item Description
1 Storage tank (capacity 3 l)
2 Inlet filter with vented cap
3 Sight-glass or level switch
4 Name plate
5 Overflow G 1/8
Connections
A
To the mechanical seal
B
From the mechanical seal
C
Filling
18.09.2012 (c) EagleBurgmann
EagleBurgmann Germany
GmbH & Co. KG
Äußere Sauerlacher Straße 6-10
82515 Wolfratshausen /Germany
Phone +49 (8171) 23-0
Fax +49 (8171) 23-1214
info@eagleburgmann.com
www.eagleburgmann.com
All technical specifications are based on extensive tests and our many years of
experience. The diversity of possible applications means, however, that they can serve
only as guide values. We must be notified of the exact conditions of application
before we can provide any guarantee for a specific case. Subject to change.