CPT-Cirprotec-A1-PHOTOVOLTAIC-APPLICATIONS-SPD-MCB-RCCB-IMD-GROUNDING-TNS0 pages
with maximum continuity of service
Insulation monitoring device (DC)
> With its Global PV Protection Concept, CPT Cirprotec extends
protection also to signal lines (CCTV, Ethernet, etc.) and prevents
further damages caused by direct lightning strikes and discharges.
A set of specific solutions of Cirprotec provide maximum COS
(Continuity of Service) to the installation: Insulation Monitoring
Device and self-reclosing MCB for the DC side, Grounding System
Monitor and self-reclosing RCCB for the AC side.
Thus assuring not only the safety of the installation, but also the
Continuity of Service, consequently, PV projects guarantee the
expected ROI.
Model
Grounding system monitor (AC)
77706703
Un
300...600
500...1000
600 Vdc
1000 Vdc
6
Ran
Modules
NEW
Code
Model
30...80 Ω
0-100 Ω
0-100 Ω
Alarm signal
Remote
Specialists in Lightning and Surge
Protection for Photovoltaic Systems
2
Alarma threshold
Remote
MCB-DC-1000
550870
Protection
String
Uoc
In
Inverter
R-CHECK
Grounding System Monitor
Self-reclosing Earth Leakage relay RCCB
• Continuous monitoring of the status
of the grounding connection.
• Insulation test which keeps the
system from reconnecting if leakage
persists.
• 4 or 8 modules, 1-phase and 3-phase.
• Idn: 30 - 300 mA
• In: 40 A
• Un: 230/400 V 50-60 Hz
Model
R-CHECK 2-40-30
R-CHECK 4-40-300-T
Code
554411
554322
Inverter
String
Phases
P+N
3P+N
Poles
600 Vdc
63 A
10 A
63 A
550 Vdc
4+1/2
5
Manual
Automatic (optional)
Remote Signal
2
Un
4
230/400 Vac 50-60Hz
In
880Vdc
Reclosure
Self
reclosure
550859
550850
1000 Vdc
Modules
G-CHECK
Self-reclosing RCCB (AC)
MCB-DC-600
550879
10 A
Un
New
230 V
2
6
Code
• Alarm output
Cirprotec
NEW
of expected ROI
G-CHECK
• Alarm threshold: 0-100 Ohms (user
defined)
77706500
Modules
30...80 Ω
G-CHECK 230 V
77706550
Un
Uoc
0% Maintenance
0% Service Interruptions
ISO-CHECK PV 1000
77706704
G-CHECK 120 V
120 V
Model
ISO-CHECK PV 600
Code
(1+IRR) t
Cirprotec PV Protection
Self-reclosing PV MCB (DC)
• Checking of the earth loop resistance
A1
Insulation & Grounding System monitors, self-reclosing MCB
& RCCB, signal line SPD, ESE lightning rod
40 A
Idn
30 mA
300 mA
4
8
Modules
Class
Yes
B curve. DC2IB class. Available with C curve for 440 Vdc models.
Reclosure
A IEC 1008.1
Timed sequence &
insulation test
Timed sequence
ESE lightning rods
Signal line SPDs
Self-reclosing
Model
Protocol 232
RF
Tel. Lines
Model
CPT-1
CPT-2
CPT-3
PSC
Model
DB9 12V9HS
CT 10 CCTV
DIN-ADSL
Code
77901100
77901200
77901300
Class I+II Lightning Arrester
Code
77820145
77801670
77840115
Level I
42 m
58 m
79 m
• Un: 230/400 V
• Iimp (10/350 µs): 12,5 kA
• Imax (8/20 µs): 65 kA
• Up (L-N) ≤ 1,3 kV
• Up (N-PE) ≤ 1,5 kV (TT)
• 4 DIN modules, 1-phase and 3-phase, plug-in.
• For highly exposed installations and/or
equipped with Lightning Protection System.
Uc
16 V
60 V
180 V
Level II
51 m
70 m
86 m
Up
<25 V (L-GND)
<500 V (L-PE)
<0,6 kV
<0,2 kV
Level III
57 m
75 m
97 m
In
0,5 kA
10 kA
5 kA
Level IV
65 m
84 m
107 m
Imax
0,5 kA
20 kA
10 kA
Wires
7+GND
BNC Connect
2
PSC4
Level of protection acc. to product standard NFC 17-102.
PSC2
PSM
Class II Surge Protector
Class II Surge Protector
• Un: 230 / 400 V
• Imax (8/20 µs): 40 kA
• Up (L-N) ≤ 1,3 kV
• Up (N-PE) ≤ 1,5 kV (TT)
• 2 or 4 DIN modules, 1-phase
and 3-phase, monobloc.
• Un: 230 / 400 V
• Imax (8/20 µs): 40 kA
• Up (L-N) ≤ 1,3 kV
• Up (N-PE) ≤ 1,5 kV (TT)
• Pluggable surge modules.
• 2 or 4 DIN modules, 1-phase and
3-phase.
CS4P
CS2P
CIRPROTEC, S.L.
Lepant, 49 - 08223 Terrassa (BARCELONA) - SPAIN
Tel. (+34) 93 733 16 84 Fax. (+34) 93 733 27 64
export@cirprotec.com
PSM4
PSM2
50080154v2
CS
Includes new plug-in SPD range and insulation monitoring device
www.cirprotec.com