Flypper Electronic Water Meter0 pages
HYDROMETER
nnnnFLYPPER ELECTRONIC WATER METER
nnnnMODELS 7- -
nnnnFLYPPER
nnnnDESCRIPTION OF OPERATION
nnnnThe rotating movement of the impeller is transferred by a
nnnnmodulator disc to the sensor system of the FLYPPER electro-
nnnnnic counter module. A built-in microprocessor evaluates the
nnnnsensor signals produced and counts the number of impeller
nnnnrevolutions, detects the direction of rotation and measu-
nnnnres the time for each revolution. The microprocessor then
nnnncalculates the volume flowing through the meter from these
nnnnparameters and adds up the meter reading. The current flow
nnnnrate is calculated from the time for one impeller rotation. The
nnnnFLYPPER module can be read out via M-Bus, LBus or optical
nnnninterface. The module is powered externally from the M-Bus
nnnnwhen this bus is connected. The internal battery is switched
nnnnoff in this case. The built-in lithium battery is rated to give
nnnnthe module a lifetime of over 10 years without an external
nnnnpower supply.
nnnnVERSIONS
nnnn□ M-Bus/pulses IP 68 - 30 °C
nnnn□ L-Bus/forward pulse IP 68 - 30 °C
nnnn□ M-Bus IP 54 - 30 °C
nnnn□ M-Bus IP 54 - 90 °C
nnnnFEATURES
nnnn□ PTB approval
nnnn□ Protection class IP 68 for multi-jet and Woltman meters
nnnnfor cold water up to 30 °C (safe up to 50 °C)
nnnn□ Protection class IP 54 for multi-jet meters for warm water
nnnnup to 90 °C
nnnn□ Current instantaneous flow rate
nnnn□ Programmable reading date
nnnn□ Primary address set to 000 ex works
nnnn□ Primary address can be changed in the field using
nnnnHYDRO-SET
nnnn□ Secondary address set to meter number ex works
nnnn□ Lithium battery guarantees lifetime longer than calibration
nnnnperiod (over 10 years if LCD switched off)
nnnn□ Convenient mechanical button for switching display
nnnn□ M-Bus interface in standard variant
nnnn□ Simultaneous M-Bus data transmission and external
nnnnpower supply
nnnn□ Pulse rates with HYDRO-SET in the field configurable
nnnn□ Up to two pulse outputs possible
nnnn□ Connectivity to an external radio module
nnnn□ Optional: L-Bus interface instead of M-Bus interface
nnnn□ 5-wire cable, 3-m long to IP 68 supplied as standard
nnnn□ 3-wire cable, 3-m long to IP 54 supplied as standard
nnnnDATASHEET
nnnn1
"